The DOI matches its Crossref record.
Comparison of arterial and venous pH, bicarbonate, PCO2 and PO2 in initial emergency department assessment
Open accessAbstract
OBJECTIVE: To determine the agreement between arterial and venous samples in a pathologically diverse patient population presenting at an emergency department (ED) with a view to obviating the need for arterial blood gas (ABG) analysis in initial ED evaluation. METHODS: Prospective study of 95 patients (69 males, 26 females, mean (SD) age 52 (1.6) years) with diverse medical conditions, presenting at a tertiary health centre ED and deemed by the treating physician to require an ABG analysis. Arterial and venous samples for gas analysis were taken as close in time to each other as possible. The data thus obtained were analysed for agreement between pH, Pco(2), Po(2) and bicarbonate using the Bland-Altman method. RESULTS: The arterial and venous values of pH, bicarbonate and Pco(2) show acceptably narrow 95% limits of agreement using the Bland-Altman method (0.13 to -0.1, 4.3 to -5.8 and 6.8 to -7.6, respectively). Agreement in Po(2) measurements was poor (95% limits of agreement 145.3 to -32.9). CONCLUSION: Venous blood gas analysis for pH, bicarbonate and Pco(2) may be a reliable substitute for ABG analysis in the initial evaluation of an adult patient population presenting to the ED.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BTS guideline for emergency oxygen use in adult patients
O'Driscoll, B. R., Howard, L. S., Davison, A. G., & on behalf of the British Thoracic Society (2008) · Thorax · doi:10.1136/thx.2008.102947 · Cited by 729
BTS guideline for oxygen use in adults in healthcare and emergency settings
O'Driscoll, B. R., Howard, L. S., Earis, J., & Mak, V (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209729 · Cited by 679
Yang, Z., Wang, Y., Zhang, Y., He, X., Zhong, C.-Q., Ni, H., Chen, X., Liang, Y., Wu, J., Zhao, S., et al. (2018) · Nature Cell Biology · doi:10.1038/s41556-017-0022-y · Cited by 285
Hypoxia and the phenomenon of immune exclusion
Pietrobon, V., & Marincola, F. M. (2021) · Journal of Translational Medicine · doi:10.1186/s12967-020-02667-4 · Cited by 119
Metadata
- Authors
- Malatesha, G., Singh, N. K., Bharija, A., Rehani, B., & Goel, A.
- Venue
- Emergency Medicine Journal
- Publisher
- BMJ
- Published
- 2007-08-01
- Volume
- 24
- Issue
- 8
- Pages
- 569-571
- ISSN
- 1351-0622 (ISSN-L)
- 1472-0205
- 1472-0213
- OpenAlex
- W2136039849
- Cited by
- 184
- References
- 0
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of arterial and venous pH, bicarbonate, PCO2 and PO2 in initial emergency department assessment. https://app.cochat.ai/papers/10.1136/emj.2007.046979
- The paper
- Malatesha, G., Singh, N. K., Bharija, A., Rehani, B., & Goel, A. (2007). Comparison of arterial and venous pH, bicarbonate, PCO2 and PO2 in initial emergency department assessment. Emergency Medicine Journal. https://doi.org/10.1136/emj.2007.046979
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.