The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction
Open accessAbstract
Background and aim: Covered self-expandable metal stents (EMS) were recently developed to overcome tumour ingrowth in conventional EMS. However, supporting evidence for the efficacy of covered EMS is lacking. Patients and methods: We enrolled 112 patients with unresectable distal biliary malignancies. They were randomly assigned to polyurethane covered (n = 57) or original diamond stent (n = 55). Results: Stent occlusion occurred in eight patients (14%) after a mean of 304 days in the covered group, and in 21 patients (38%) after a mean of 166 days in the uncovered group. The incidence of covered EMS occlusion was significantly lower than that of uncovered EMS (p = 0.0032). The cumulative stent patency of covered stents was significantly higher than that of uncovered stents (p = 0.0066). No tumour ingrowth occurred in the covered group while it was observed in 15 patients in the uncovered group. In subgroup analysis, the cumulative patency of the covered EMS was significantly higher in pancreatic cancer (p = 0.0363) and metastatic lymph nodes (p = 0.0354). There was no significant difference in survival between the two groups. Acute cholecystitis was observed in two of the covered group and in none of the uncovered group. Mild pancreatitis occurred in five of the covered group and in one of the uncovered group. Conclusions: Covered diamond stents successfully prevented tumour ingrowth and were significantly superior to uncovered stents for the treatment of patients with distal malignant biliary obstruction. However, careful attention must be paid to complications specific to covered self-expandable metal stents, such as acute cholecystitis and pancreatitis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peto, R., Pike, M. C., Armitage, P., Breslow, N. E., Cox, D. R., Howard, S. V., Mantel, N., McPherson, K., Peto, J., & Smith, P. G. (1977) · British Journal of Cancer · doi:10.1038/bjc.1977.1 · Cited by 8,285
WHO Handbook for Reporting Results of Cancer Treatment
Palmer, M. K. (1982) · British Journal of Cancer · doi:10.1038/bjc.1982.83 · Cited by 2,198
Group sequential methods in the design and analysis of clinical trials
POCOCK, S. J. (1977) · Biometrika · doi:10.1093/biomet/64.2.191 · Cited by 1,831
WHO handbook for reporting results of cancer treatment
Sylvester, R. (1980) · Controlled Clinical Trials · doi:10.1016/0197-2456(80)90009-4 · Cited by 1,055
Davids, P. H. P., Groen, A. K., Rauws, E. A., Tytgat, G. N. J., & Huibregtse, K. (1992) · The Lancet · doi:10.1016/0140-6736(92)92752-2 · Cited by 999
Smith, A. C., Dowsett, J. F., Russell, R. C. G., Hatfield, A. R., & Cotton, P. B. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90455-3 · Cited by 824
Komatsu, Y., Kawabe, T., Toda, N., Ohashi, M., Isayama, M., Tateishi, K., Sato, S., Koike, Y., Yamagata, M., Tada, M., et al. (1998) · Endoscopy · doi:10.1055/s-2007-993721 · Cited by 189
Self-citationClinical Experience with Covered Wallstents for Biliary Malignancies: 23-Month Follow-Up
Rossi, P., Bezzi, M., Salvatori, F. M., Panzetti, C., Rossi, M., & Pavia, G. (1997) · CardioVascular and Interventional Radiology · doi:10.1007/s002709900190 · Cited by 99
In Vitro and in Vivo Biodurability of a Compliant Microporous Vascular Graft
Edwards, A. C., Carson, R. J., Szycher, M., & Bowald, S. (1998) · Journal of Biomaterials Applications · doi:10.1177/088532829801300102 · Cited by 58
Cited by
Razumilava, N., & Gores, G. J. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61903-0 · Cited by 1,729
Khan, S. A., Thomas, H. C., Davidson, B. R., & Taylor-Robinson, S. D. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67530-7 · Cited by 1,042
Guidelines for the diagnosis and treatment of cholangiocarcinoma: an update
Khan, S. A., Davidson, B. R., Goldin, R. D., Heaton, N., Karani, J., Pereira, S. P., Rosenberg, W. M. C., Tait, P., Taylor-Robinson, S. D., Thillainayagam, A. V., et al. (2012) · Gut · doi:10.1136/gutjnl-2011-301748 · Cited by 797
Soderlund, C., & Linder, S. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.11.052 · Cited by 324
Classification, Diagnosis, and Management of Cholangiocarcinoma
Razumilava, N., & Gores, G. J. (2013) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2012.09.009 · Cited by 312
Metadata
- Authors
- Isayama, H., Komatsu, Y., Tsujino, T., Sasahira, N., Hirano, K., Toda, N., Nakai, Y., Yamamoto, N., Tada, M., Yoshida, H., Shiratori, Y., Kawabe, T., & Omata, M.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 2004-04-13
- Volume
- 53
- Issue
- 5
- Pages
- 729-734
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2105725898
- Cited by
- 636
- References
- 9
- FWCI
- 18.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction. https://app.cochat.ai/papers/10.1136/gut.2003.018945
- The paper
- Isayama, H., Komatsu, Y., Tsujino, T., Sasahira, N., Hirano, K., Toda, N., Nakai, Y., Yamamoto, N., Tada, M., Yoshida, H., Shiratori, Y., Kawabe, T., & Omata, M. (2004). A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction. Gut. https://doi.org/10.1136/gut.2003.018945
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.