Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 636

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction

Open access
Isayama, H, Komatsu, Y, Tsujino, T, Sasahira, N, Hirano, K, Toda, N, Nakai, Y, Yamamoto, N, Tada, M, Yoshida, H, Shiratori, Y, Kawabe, T, Omata, M·2004·Gut

Abstract

Background and aim: Covered self-expandable metal stents (EMS) were recently developed to overcome tumour ingrowth in conventional EMS. However, supporting evidence for the efficacy of covered EMS is lacking. Patients and methods: We enrolled 112 patients with unresectable distal biliary malignancies. They were randomly assigned to polyurethane covered (n = 57) or original diamond stent (n = 55). Results: Stent occlusion occurred in eight patients (14%) after a mean of 304 days in the covered group, and in 21 patients (38%) after a mean of 166 days in the uncovered group. The incidence of covered EMS occlusion was significantly lower than that of uncovered EMS (p = 0.0032). The cumulative stent patency of covered stents was significantly higher than that of uncovered stents (p = 0.0066). No tumour ingrowth occurred in the covered group while it was observed in 15 patients in the uncovered group. In subgroup analysis, the cumulative patency of the covered EMS was significantly higher in pancreatic cancer (p = 0.0363) and metastatic lymph nodes (p = 0.0354). There was no significant difference in survival between the two groups. Acute cholecystitis was observed in two of the covered group and in none of the uncovered group. Mild pancreatitis occurred in five of the covered group and in one of the uncovered group. Conclusions: Covered diamond stents successfully prevented tumour ingrowth and were significantly superior to uncovered stents for the treatment of patients with distal malignant biliary obstruction. However, careful attention must be paid to complications specific to covered self-expandable metal stents, such as acute cholecystitis and pancreatitis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.2003.018945

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 636

Metadata

Authors
Isayama, H., Komatsu, Y., Tsujino, T., Sasahira, N., Hirano, K., Toda, N., Nakai, Y., Yamamoto, N., Tada, M., Yoshida, H., Shiratori, Y., Kawabe, T., & Omata, M.
Venue
Gut
Publisher
BMJ
Published
2004-04-13
Volume
53
Issue
5
Pages
729-734
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2105725898
Cited by
636
References
9
FWCI
18.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction. https://app.cochat.ai/papers/10.1136/gut.2003.018945
The paper
Isayama, H., Komatsu, Y., Tsujino, T., Sasahira, N., Hirano, K., Toda, N., Nakai, Y., Yamamoto, N., Tada, M., Yoshida, H., Shiratori, Y., Kawabe, T., & Omata, M. (2004). A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction. Gut. https://doi.org/10.1136/gut.2003.018945

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.