Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 273

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Evaluation of oesophageal mucosa integrity by the intraluminal impedance technique

Farré, Ricard, Blondeau, Kathleen, Clement, Dominique, Vicario, Maria, Cardozo, Lucia, Vieth, Michael, Mertens, Veerle, Pauwels, Ans, Silny, Jiri, Jimenez, Marcel, Tack, Jan, Sifrim, Daniel · 2011 · Gut

Abstract

Background: Oesophageal intraluminal impedance is currently used for assessment of reflux in gastro-oesophageal reflux disease (GORD). Oesophageal mucosa integrity may have a key role in heartburn perception in non-erosive reflux disease (NERD). Severe erosive oesophagitis is associated with low impedance baseline. We hypothesised that impedance baseline measurements could be used to evaluate changes in oesophageal mucosa integrity in man. Methods: We measured oesophageal impedance baseline before, during and after acid perfusion in rabbits and healthy subjects. Transepithelial resistance (TER) was determined and dilated intercellular spaces (DIS) were assessed in isolated rabbit oesophageal mucosa. Impedance baseline was measured retrospectively at different levels of the oesophagus in impedance-pH recordings from asymptomatic volunteers and patients with GORD. Results: In healthy subjects and rabbits, impedance baseline dropped dramatically during perfusion of control solution (pH 7.2) but after perfusion, impedance recovered. In rabbits, after perfusion with saline pH 1.5 and 1.0 impedance values remained a 39.1±7.0% and 63.9±6.5% (p<0.05) lower respectively. There was a positive correlation between in vivo basal impedance and in vitro TER values (r=0.72, p=0.0021). Tissue showed no erosions but both acidic solutions induced DIS. In healthy subjects, after perfusion with saline pH 2.0 and 1.0 the impedance baseline remained lower a 21.9±6.5% and 52.7±5.0%, (p<0.0001) respectively. Patients with GORD have a lower impedance baseline than healthy volunteers at the distal oesophagus. Conclusions: Impedance baseline measurements might be used to evaluate the status of the oesophageal mucosa and to study the role of the impaired mucosal integrity in acid-induced heartburn in healthy volunteers and in patients with GORD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.2010.233049

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 273

Metadata

Authors
Farré, R., Blondeau, K., Clement, D., Vicario, M., Cardozo, L., Vieth, M., Mertens, V., Pauwels, A., Silny, J., Jimenez, M., Tack, J., & Sifrim, D.
Venue
Gut
Publisher
BMJ
Published
2011-02-08
Volume
60
Issue
7
Pages
885-892
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2125790295
Cited by
273
References
21
FWCI
13.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of oesophageal mucosa integrity by the intraluminal impedance technique. https://app.cochat.ai/papers/10.1136/gut.2010.233049
The paper
Farré, R., Blondeau, K., Clement, D., Vicario, M., Cardozo, L., Vieth, M., Mertens, V., Pauwels, A., Silny, J., Jimenez, M., Tack, J., & Sifrim, D. (2011). Evaluation of oesophageal mucosa integrity by the intraluminal impedance technique. Gut. https://doi.org/10.1136/gut.2010.233049

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.