Transcutaneous Doppler ultrasound measurement of superior mesenteric artery blood flow in man.

Open access
Qamar, M I, Read, A E, Skidmore, R, Evans, J M, Wells, P N · 1986 · Gut
Cited by 141

The DOI matches its Crossref record.

Abstract

A duplex scanner which consists of a real time two dimensional scanner and a pulsed Doppler flowmeter was used to measure superior mesenteric blood flow in 70 healthy subjects. By processing the Doppler shift signals, the instantaneous average Doppler shift frequency and then the instantaneous average velocity of the flow rate were calculated. Both diameter of the vessel and angle between vessel and beam were measured from real time imaging. The mean (+/- standard error of the mean) of the superior mesenteric blood flow was 517 +/- 19 ml/min. There was neither significant difference in flow between sexes, nor correlation between flow and age (r = 0.042). The mean of coefficients of variability were 6.8% over the short term, and 8.2% in long term studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.27.1.100

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 141

Metadata

Authors
Qamar, M. I., Read, A. E., Skidmore, R., Evans, J. M., & Wells, P. N.
Venue
Gut
Publisher
BMJ
Published
1986-01
Volume
27
Issue
1
Pages
100-105
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2155481860
Cited by
141
References
0
FWCI
9.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcutaneous Doppler ultrasound measurement of superior mesenteric artery blood flow in man. https://app.cochat.ai/papers/10.1136/gut.27.1.100
The paper
Qamar, M. I., Read, A. E., Skidmore, R., Evans, J. M., & Wells, P. N. (1986). Transcutaneous Doppler ultrasound measurement of superior mesenteric artery blood flow in man. Gut. https://doi.org/10.1136/gut.27.1.100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.