CoChat

Percutaneous endoscopic gastrostomy in a general hospital: prospective evaluation of indications, outcome, and randomised comparison of two tube designs.

Open access
Panos, M Z, Reilly, H, Moran, A, Reilly, T, Wallis, P J, Wears, R, Chesner, I M · 1994 · Gut
Cited by 58

The DOI matches its Crossref record.

Abstract

The indications for percutaneous endoscopic gastrostomy (PEG) and patient outcome, were examined prospectively in the setting of a general hospital. In the course of 26 months, 76 patients underwent PEG (median age 62 years (range 18-99)) and were followed up for 6887 patient days. The median (range) duration of PEG feeding was 93 (3-785) days. The procedure was carried out for neurological indications in 76% of cases (stroke 51%) and 53% of patients were severely malnourished (body mass index < 17 kg/m2) at the time of referral. In 12 (16%) patients swallowing recovered and the PEG was removed after a median (range) of 55 days (20-150). Three (4%) deaths were related to PEG (one oesophageal perforation, one haemorrhage, and one aspiration pneumonia). One patient developed peritonism and ileus, which resolved with conservative treatment. Minor complications included local sepsis 3%, tube blockage 12%, and tube connector leak 5%. During seven days of observation, demands on nursing time for routine care of the PEG were the same as for nasogastric tube feeding, median (range) 21 (4-42) v 16 (4-40) min/day respectively, but in about half the latter cases the tube had to be replaced at least once. Over 15 months, 29 patients were randomised to receive a 1.9 mm inner, 2.9 mm (9F) outer diameter Fresenius and 27 a 3.0 mm inner, 4.0 mm (12F) outer diameter Bower polyurethane tube and were followed for 2920 and 2388 patient days respectively. There was no difference in the insertion time (median (range) 20 (10-45) v 24 (10-45) min respectively) or number of patients with complications (three v eight patients NS), although there were more minor mechanical problems (three v 12, p < 0.01) with the 12F tube. The internal anchoring device of the 12F tube allowed its non-endoscopic removal, a method applicable too 16% of cases. No tubes were removed because of blockage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.35.11.1551

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 58

Metadata

Authors
Panos, M. Z., Reilly, H., Moran, A., Reilly, T., Wallis, P. J., Wears, R., & Chesner, I. M.
Venue
Gut
Publisher
BMJ
Published
1994-11
Volume
35
Issue
11
Pages
1551-1556
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2026324880
Cited by
58
References
0
FWCI
3.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous endoscopic gastrostomy in a general hospital: prospective evaluation of indications, outcome, and randomised comparison of two tube designs. https://app.cochat.ai/papers/10.1136/gut.35.11.1551
The paper
Panos, M. Z., Reilly, H., Moran, A., Reilly, T., Wallis, P. J., Wears, R., & Chesner, I. M. (1994). Percutaneous endoscopic gastrostomy in a general hospital: prospective evaluation of indications, outcome, and randomised comparison of two tube designs. Gut. https://doi.org/10.1136/gut.35.11.1551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.