CoChat

Increased gastric Pco 2 during exercise is indicative of gastric ischaemia: a tonometric study

Open access
Kolkman, J J, Groeneveld, A B J, van der Berg, F G, Rauwerda, J A, Meuwissen, S G M · 1999 · Gut
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Diagnosis of gastric ischaemia is difficult and angiography is an invasive procedure. Angiographic findings may not correlate with clinical importance. Aims: To investigate whether tonometric measurement of intragastric P co 2 during exercise can be used to detect clinically important gastric ischaemia. Methods: Fourteen patients with unexplained abdominal pain or weight loss were studied. Splanchnic angiography served as the gold standard. Three patients were studied again after a revascularisation procedure. Gastric P co 2 was measured from a nasogastric tonometer, with 10 minute dwell times, and after acid suppression. Gastric and capillary P co 2 were measured before, during, and after submaximal exercise of 10 minutes duration. Results: Seven patients had normal angiograms; seven had more than 50% stenosis in the coeliac (n=7) or superior mesenteric artery (n=4). Normal subjects showed no changes in tonometry. In patients with stenoses, the median intragastric P co 2 (Pi co 2 ) at rest was 5.2 kPa (range 4.8–11.2) and rose to 6.4 kPa (range 5.7–15.7) at peak exercise; the median intragastric blood P co 2 gradient increased from 0.0 kPa (range −0.8 to 5.9) to 1.7 kPa (range 0.9 to 10.3; p<0.01). Only two subjects had abnormal tonometry at rest; all had supernormal values at peak exercise. The P co 2 gradient correlated with clinical and gastroscopic severity; in patients reexamined after revascularisation (n=3), exercise tonometry returned to normal. Conclusion: Gastric tonometry during exercise is a promising non-invasive tool for diagnosing and grading gastrointestinal ischaemia and evaluating the results of revascularisation surgery for symptomatic gastric ischaemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.44.2.163

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Mesenteric duplex scanning: A blinded prospective study

    Moneta, G. L., Lee, R. W., Yeager, R. A., Taylor, L. M., & Porter, J. M. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90011-a · Cited by 283 · cited 1×

    “Furthermore, the blood flow parameters obtained with duplex ultrasonography of the splanchnic vessels may have no relation to the presence or severity of ischaemia, and may have considerable overlap with normal subjects.”
    Background
  • Effects of exercise on mesenteric blood flow in man.

    Qamar, M. I., & Read, A. E. (1987) · Gut · doi:10.1136/gut.28.5.583 · Cited by 234 · cited 1×

    “We therefore looked for an alternative measure to provoke ischaemia. An exercise test might serve that goal, as it stresses the abdominal vasodilator reserve by diverting blood flow from the splanchnic circulation to the exercising muscles, with a reduction in superior mesenteric artery blood flow of 43%, as shown in…”
    Background

Show all 2 references

Cited by

Metadata

Authors
Kolkman, J. J., Groeneveld, A. B. J., van der Berg, F. G., Rauwerda, J. A., & Meuwissen, S. G. M.
Venue
Gut
Publisher
BMJ
Published
1999-02-01
Volume
44
Issue
2
Pages
163-167
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2160742895
Cited by
45
References
2
FWCI
2.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.