Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record.

Bowel ultrasound in assessment of Crohn's disease and detection of related small bowel strictures: a prospective comparative study versus x ray and intraoperative findings

Open access
Parente, F, Maconi, G, Bollani, S, Anderloni, A, Sampietro, G, Cristaldi, M, Franceschelli, N, Bianco, R, Taschieri, A M, Bianchi Porro, G · 2002 · Gut

Abstract

Background and aim: Despite the fact that bowel ultrasound (US) has recently been proved to be useful in the assessment of bowel diseases, uncertainty persists as to its diagnostic role in patients with complicated Crohn's disease (CD). Therefore, we have prospectively investigated the accuracy of US compared with x ray procedures and intraoperative findings in detecting small bowel strictures complicating CD as well as its reliability in assessing disease extent and location within the bowel. Methods: A series of 296 consecutive patients with proven CD admitted to L Sacco University Hospital between 1997 and 1999, having undergone complete radiographic evaluation (including small bowel x ray, colonoscopy, or double contrast barium enema), were enrolled in the study. Bowel US was performed in each patient by two experienced operators unaware of the results of other diagnostic procedures. The accuracy of US in detecting strictures compared with x ray studies was determined separately in two different groups of patients: 211 patients treated conservatively (non-operative CD) and 85 patients who were candidates for surgery for CD complications or unresponsiveness to medical therapy (operative CD). Results: Overall sensitivity and specificity of US in assessing the anatomical distribution of CD were 93% and 97%, respectively. The extent of ileal disease measured at US correlated well with that determined by x ray ( r =0.52, p<0.001) in medically treated patients as well as with that measured intraoperatively in surgical patients ( r =0.64, p<0.001). One or more stenoses were detected in 75 patients (35.5%) at small bowel enteroclysis in the non-operative CD group compared with 70 (82%) in the operative CD series. Sensitivity, specificity, and positive predictive values of bowel US in the detection of strictures were 79%, 98%, and 95% in non-operative CD patients and 90%, 100%, and 100% in operative CD cases, respectively. Conclusions: In experienced hands, bowel US is an accurate technique for assessing CD extent and location and is very helpful in detecting small bowel strictures, especially in very severe cases that are candidates for surgery. The use of bowel US is therefore justified as a primary investigation in CD patients in whom complications are suspected.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.50.4.490

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Parente, F., Maconi, G., Bollani, S., Anderloni, A., Sampietro, G., Cristaldi, M., Franceschelli, N., Bianco, R., Taschieri, A. M., & Bianchi Porro, G.
Venue
Gut
Publisher
BMJ
Published
2002-04
Volume
50
Issue
4
Pages
490-495
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2021911121
Cited by
186
References
0
FWCI
4.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bowel ultrasound in assessment of Crohn's disease and detection of related small bowel strictures: a prospective comparative study versus x ray and intraoperative findings. https://app.cochat.ai/papers/10.1136/gut.50.4.490
The paper
Parente, F., Maconi, G., Bollani, S., Anderloni, A., Sampietro, G., Cristaldi, M., Franceschelli, N., Bianco, R., Taschieri, A. M., & Bianchi Porro, G. (2002). Bowel ultrasound in assessment of Crohn's disease and detection of related small bowel strictures: a prospective comparative study versus x ray and intraoperative findings. Gut. https://doi.org/10.1136/gut.50.4.490

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.