The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Establishment of standardised SLA/LP immunoassays: specificity for autoimmune hepatitis, worldwide occurrence, and clinical characteristics
Open accessAbstract
Background: Antibodies to soluble liver antigen/liver pancreas (SLA/LP) are specific markers of autoimmune hepatitis. Their target antigen has recently been cloned. Aims: To establish standardised immunoassays using the recombinant antigen, and to assess the frequency and significance of seropositivity in patients from different countries. Methods: An enzyme linked immunoassay was developed using purified recombinant antigen and validated by testing sera from 200 healthy blood donors and 1026 patients with various liver and non-liver diseases. The assay was then applied to 454 sera from 419 patients with autoimmune hepatitis from different countries. All sera were also tested by inhibition immunoassay and western blot. Results: Antibodies were reliably detected by the recombinant immunoassay and occurred exclusively in patients with autoimmune liver disease. Twenty three of 149 patients from the USA (15%), 23/132 from Brazil (17%), 21/108 from Germany (19%), and 2/30 from Japan (7%) were seropositive. Clinical features at presentation were similar between seropositive and seronegative patients. However, relapse after corticosteroid withdrawal or during maintenance therapy occurred more commonly in seropositive patients. Conclusions: Antibodies to SLA/LP can be reliably detected by these standardised immunoassays based on recombinant antigen. Antibodies to SLA/LP occur with similar frequencies in different geographical regions, races, and age groups, and are of exquisite diagnostic specificity. Whether SLA/LP positive patients represent a clinically distinct subgroup remains to be determined; relapse during treatment reduction appeared to be more common in the SLA/LP group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lohse, A. W., zum Büschenfelde, K.-H. M., Franz, B., Kanzler, S., Gerken, G., & Dienes, H.-P. (1999) · Hepatology · doi:10.1002/hep.510290409 · Cited by 278
Self-citation
Cited by
Simplified criteria for the diagnosis of autoimmune hepatitis
Hennes, E. M., Zeniya, M., Czaja, A. J., Parés, A., Dalekos, G. N., Krawitt, E. L., Bittencourt, P. L., Porta, G., Boberg, K. M., Hofer, H., et al. (2008) · Hepatology · doi:10.1002/hep.22322 · Cited by 1,901
Self-citationDiagnosis and management of autoimmune hepatitis
Manns, M. P., Czaja, A. J., Gorham, J. D., Krawitt, E. L., Mieli-Vergani, G., Vergani, D., & Vierling, J. M. (2010) · Hepatology · doi:10.1002/hep.23584 · Cited by 1,442
Self-citationEASL Clinical Practice Guidelines: autoimmune hepatitis
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.06.030 · Cited by 1,245
Mack, C. L., Adams, D., Assis, D. N., Kerkar, N., Manns, M. P., Mayo, M. J., Vierling, J. M., Alsawas, M., Murad, M. H., & Czaja, A. J. (2020) · Hepatology · doi:10.1002/hep.31065 · Cited by 983
Self-citationRequirements for Minimum Sample Size for Sensitivity and Specificity Analysis
Bujang, M. A. (2016) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2016/18129.8744 · Cited by 624
Metadata
- Authors
- Baeres, M., Herkel, J., Czaja, A. J., Wies, I., Kanzler, S., Cancado, E. L. R., Porta, G., Nishioka, M., Simon, T., Daehnrich, C., Schlumberger, W., Galle, P. R., & Lohse, A. W.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 2002-08
- Volume
- 51
- Issue
- 2
- Pages
- 259-264
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2152103678
- Cited by
- 184
- References
- 1
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Establishment of standardised SLA/LP immunoassays: specificity for autoimmune hepatitis, worldwide occurrence, and clinical characteristics. https://app.cochat.ai/papers/10.1136/gut.51.2.259
- The paper
- Baeres, M., Herkel, J., Czaja, A. J., Wies, I., Kanzler, S., Cancado, E. L. R., Porta, G., Nishioka, M., Simon, T., Daehnrich, C., Schlumberger, W., Galle, P. R., & Lohse, A. W. (2002). Establishment of standardised SLA/LP immunoassays: specificity for autoimmune hepatitis, worldwide occurrence, and clinical characteristics. Gut. https://doi.org/10.1136/gut.51.2.259
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.