The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding
Open accessAbstract
Background: The development of wireless capsule endoscopy allows painless imaging of the small intestine. Its clinical use is not yet defined. The aim of this study was to compare the clinical efficacy and technical performance of capsule endoscopy and push enteroscopy in a series of 50 patients with colonoscopy and gastroscopy negative gastrointestinal bleeding. Methods: A wireless capsule endoscope was used containing a CMOS colour video imager, transmitter, and batteries. Approximately 50 000 transmitted images are received by eight abdominal aerials and stored on a portable solid state recorder, which is carried on a belt. Push enteroscopy was performed using a 240 cm Olympus video enteroscope. Results: Studies in 14 healthy volunteers gave information on normal anatomical appearances and preparation. In 50 patients with gastrointestinal bleeding and negative colonoscopy and gastroscopy, push enteroscopy was compared with capsule endoscopy. A bleeding source was discovered in the small intestine in 34 of 50 patients (68%). These included angiodysplasia (16), focal fresh bleeding (eight), apthous ulceration suggestive of Crohn’s disease (three), tumour (two), Meckel’s diverticulum (two), ileal ulcer (one), jejunitis (one), and ulcer due to intussusception (one). One additional intestinal diagnosis was made by enteroscopy. The yield of push enteroscopy in evaluating obscure bleeding was 32% (16/50). The capsule identified significantly more small intestinal bleeding sources than push enteroscopy (p<0.05). Patients preferred capsule endoscopy to push enteroscopy (p<0.001). Conclusions: In this study capsule endoscopy was superior to push enteroscopy in the diagnosis of recurrent bleeding in patients who had a negative gastroscopy and colonoscopy. It was safe and well tolerated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Self-citationColonoscopic miss rates of adenomas determined by back-to-back colonoscopies
Rex, D., Cutler, C., Lemmel, G., Rahmani, E., Clark, D., Helper, D., Lehman, G., & Mark, D. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70214-2 · Cited by 1,553
Ell, C., Remke, S., May, A., Helou, L., Henrich, R., & Mayer, G. (2002) · Endoscopy · doi:10.1055/s-2002-33446 · Cited by 635
Zuckerman, G. R., Gyawali, C. P., Askin, M. P., & Lewis, B. S. (2000) · Gastroenterology · doi:10.1016/s0016-5085(00)70430-6 · Cited by 501
Appleyard, M. N., Fireman, Z., Glukhovsky, A., et al. (2000) · Gastroenterology · doi:10.1053/gast.2000.20844 · Cited by 415
A Flexible Fibrescope, using Static Scanning
HOPKINS, H. H., & KAPANY, N. S. (1954) · Nature · doi:10.1038/173039b0 · Cited by 370
Small intestinal length: a factor essential for gut adaptation.
Weaver, L. T., Austin, S., & Cole, T. J. (1991) · Gut · doi:10.1136/gut.32.11.1321 · Cited by 259
Occult Gastrointestinal Bleeding
Rockey, D. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907013410107 · Cited by 212
Zaman, A., & Katon, R. M. (1998) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(98)70221-4 · Cited by 174
Failure of colonoscopy to detect colorectal cancer: evaluation of 47 cases in 20 hospitals
Haseman, J. H., Lemmel, G. T., Rahmani, E. Y., & Rex, D. K. (1997) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(97)70172-x · Cited by 167
Cited by
ACG Clinical Guideline: Diagnosis and Management of Small Bowel Bleeding
Gerson, L. B., Fidler, J. L., Cave, D. R., & Leighton, J. A. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.246 · Cited by 719
Markers to measure immunomodulation in human nutrition intervention studies
Albers, R., Antoine, J.-M., Bourdet-Sicard, R., Calder, P. C., Gleeson, M., Lesourd, B., Samartín, S., Sanderson, I. R., Van Loo, J., Vas Dias, F. W., et al. (2005) · British Journal of Nutrition · doi:10.1079/bjn20051469 · Cited by 286
A Preliminary Analysis of Self-Supervision for Wireless Capsule Endoscopy
Vats, A., Pedersen, M., & Mohammed, A. (2021) · 2021 9th European Workshop on Visual Information Processing (EUVIP) · doi:10.1109/euvip50544.2021.9484012 · Cited by 5
Metadata
- Authors
- Mylonaki, M., Fritscher-Ravens, A., & Swain, P.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 2003-07-15
- Volume
- 52
- Issue
- 8
- Pages
- 1122-1126
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2107694023
- Cited by
- 477
- References
- 10
- FWCI
- 39.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding. https://app.cochat.ai/papers/10.1136/gut.52.8.1122
- The paper
- Mylonaki, M., Fritscher-Ravens, A., & Swain, P. (2003). Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding. Gut. https://doi.org/10.1136/gut.52.8.1122
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.