Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Standard endoscopy with random biopsies versus narrow band imaging targeted biopsies in Barrett's oesophagus: a prospective, international, randomised controlled trial

Sharma, Prateek, Hawes, Robert H, Bansal, Ajay, Gupta, Neil, Curvers, Wouter, Rastogi, Amit, Singh, Mandeep, Hall, Matt, Mathur, Sharad C, Wani, Sachin B, Hoffman, Brenda, Gaddam, Srinivas, Fockens, Paul, Bergman, Jacques J·2013·Gut

Abstract

Background: White light endoscopy with random biopsies is the standard for detection of intestinal metaplasia (IM) and neoplasia in patients with Barrett's oesophagus (BO). Narrow band imaging (NBI) highlights surface patterns that correlate with IM and neoplasia in BO. Objective: To compare high-definition white light (HD-WLE) and NBI for detection of IM and neoplasia in BO. Design: International, randomised, crossover trial comparing HD-WLE and NBI. Patients referred for BO screening/surveillance at three tertiary referral centres were prospectively enrolled and randomised to HD-WLE or NBI followed by other procedures in 3–8 weeks. During HD-WLE, four quadrant biopsies every 2 cm, together with targeted biopsies of visible lesions (Seattle protocol), were obtained. During NBI examination, mucosal and vascular patterns were noted and targeted biopsies were obtained. All biopsies were read by a single expert gastrointestinal pathologist in a blinded fashion. Results: 123 patients with BO (mean age 61; 93% male; 97% Caucasian) with mean circumferential and maximal extents of 1.8 and 3.6 cm, respectively, were enrolled. Both HD-WLE and NBI detected 104/113 (92%) patients with IM, but NBI required fewer biopsies per patient (3.6 vs 7.6, p<0.0001). NBI detected a higher proportion of areas with dysplasia (30% vs 21%, p=0.01). During examination with NBI, all areas of high-grade dysplasia and cancer had an irregular mucosal or vascular pattern. Conclusions: NBI targeted biopsies can have the same IM detection rate as an HD-WLE examination with the Seattle protocol while requiring fewer biopsies. In addition, NBI targeted biopsies can detect more areas with dysplasia. Regular appearing NBI surface patterns did not harbour high-grade dysplasia/cancer, suggesting that biopsies could be avoided in these areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2011-300962

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 375

Metadata

Authors
Sharma, P., Hawes, R. H., Bansal, A., Gupta, N., Curvers, W., Rastogi, A., Singh, M., Hall, M., Mathur, S. C., Wani, S. B., Hoffman, B., Gaddam, S., Fockens, P., & Bergman, J. J.
Venue
Gut
Publisher
BMJ
Published
2012-02-07
Volume
62
Issue
1
Pages
15-21
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2129797859
Cited by
375
References
10
FWCI
34.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standard endoscopy with random biopsies versus narrow band imaging targeted biopsies in Barrett's oesophagus: a prospective, international, randomised controlled trial. https://app.cochat.ai/papers/10.1136/gutjnl-2011-300962
The paper
Sharma, P., Hawes, R. H., Bansal, A., Gupta, N., Curvers, W., Rastogi, A., Singh, M., Hall, M., Mathur, S. C., Wani, S. B., Hoffman, B., Gaddam, S., Fockens, P., & Bergman, J. J. (2013). Standard endoscopy with random biopsies versus narrow band imaging targeted biopsies in Barrett's oesophagus: a prospective, international, randomised controlled trial. Gut. https://doi.org/10.1136/gutjnl-2011-300962

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.