CoChat

Random comparison of repeated faecal immunochemical testing at different intervals for population-based colorectal cancer screening

Open access
van Roon, Aafke H C, Goede, S Luuk, van Ballegooijen, Marjolein, van Vuuren, Anneke J, Looman, Caspar W N, Biermann, Katharina, Reijerink, Jacqueline C I Y, Mannetje, Hans 't, van der Togt, Alexandra C M, Habbema, J Dik F, van Leerdam, Monique E, Kuipers, Ernst J · 2013 · Gut
Cited by 138

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Colorectal cancer screening by means of faecal immunochemical tests (FITs) requires successive screening rounds for an optimal preventive effect. However, data on the influence of the length of the screening interval on participation and diagnostic yield are lacking. Repeated FIT screening was therefore performed in a population-based trial comparing various repeat intervals. DESIGN: 7501 Dutch individuals aged 50-74 years were randomly selected and invited for two 1-sample FIT screening rounds (haemoglobin (Hb) concentration ≥ 50 ng/ml, corresponding to 10 μg Hb/g faeces) with intervals of 1 (group I), 2 (group II) or 3 years (group III). RESULTS: In group I, participation was 64.7% in the first screening round and 63.2% in the second. The corresponding percentages for groups II and III were 61.0% vs 62.5% and 62.0% vs 64.0%. Triennial screening resulted in a higher participation rate in the second screening round compared with annual screening (p=0.04). The overall positivity rate in the second screening round was significantly lower compared with the first round (6.0% vs 8.4%; OR 0.69, 95% CI 0.58 to 0.82) and did not depend on interval length (p=0.23). Similarly, the overall detection rate of advanced neoplasia was significantly lower in the second round compared with the first screening round (1.9% vs 3.3%; OR 0.57, 95% CI 0.43 to 0.76) and also did not depend on interval length (p=0.62). The positive predictive value of the FIT did not significantly change over time (41% vs 33%; p=0.07). CONCLUSION: The total number of advanced neoplasia found at repeat FIT screening is not influenced by the interval length within a range of 1-3 years. Furthermore, there is a stable and acceptably high participation in the second screening round. This implies that screening intervals can be tailored to local resources.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2011-301583

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 138

Metadata

Authors
van Roon, A. H. C., Goede, S. L., van Ballegooijen, M., van Vuuren, A. J., Looman, C. W. N., Biermann, K., Reijerink, J. C. I. Y., Mannetje, H. '., van der Togt, A. C. M., Habbema, J. D. F., van Leerdam, M. E., & Kuipers, E. J.
Venue
Gut
Publisher
BMJ
Published
2012-03-02
Volume
62
Issue
3
Pages
409-415
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2146047390
Cited by
138
References
1
FWCI
6.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Random comparison of repeated faecal immunochemical testing at different intervals for population-based colorectal cancer screening. https://app.cochat.ai/papers/10.1136/gutjnl-2011-301583
The paper
van Roon, A. H. C., Goede, S. L., van Ballegooijen, M., van Vuuren, A. J., Looman, C. W. N., Biermann, K., Reijerink, J. C. I. Y., Mannetje, H. '., van der Togt, A. C. M., Habbema, J. D. F., van Leerdam, M. E., & Kuipers, E. J. (2013). Random comparison of repeated faecal immunochemical testing at different intervals for population-based colorectal cancer screening. Gut. https://doi.org/10.1136/gutjnl-2011-301583

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.