CoChat

Claudin-4-targeted optical imaging detects pancreatic cancer and its precursor lesions

Neesse, Albrecht, Hahnenkamp, Anke, Griesmann, Heidi, Buchholz, Malte, Hahn, Stefan A, Maghnouj, Abdelouahid, Fendrich, Volker, Ring, Janine, Sipos, Bence, Tuveson, David A, Bremer, Christoph, Gress, Thomas M, Michl, Patrick · 2013 · Gut
Cited by 77

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Novel imaging methods based on specific molecular targets to detect both established neoplasms and their precursor lesions are highly desirable in cancer medicine. Previously, we identified claudin-4, an integral constituent of tight junctions, as highly expressed in various gastrointestinal tumours including pancreatic cancer. Here, we investigate the potential of targeting claudin-4 with a naturally occurring ligand to visualise pancreatic cancer and its precursor lesions in vitro and in vivo by near-infrared imaging approaches. DESIGN: A non-toxic C-terminal fragment of the claudin-4 ligand Clostridium perfringens enterotoxin (C-CPE) was labelled with a cyanine dye (Cy5.5). Binding of the optical tracer was analysed on claudin-4 positive and negative cells in vitro, and tumour xenografts in vivo. In addition, two genetically engineered mouse models for pancreatic intraepithelial neoplasia (PanIN) and pancreatic cancer were used for in vivo validation. Optical imaging studies were conducted using 2D planar fluorescence reflectance imaging (FRI) technology and 3D fluorescence-mediated tomography (FMT). RESULTS: In vitro, the peptide-dye conjugate showed high binding affinity to claudin-4 positive CAPAN1 cells, while claudin-4 negative HT1080 cells revealed little or no fluorescence. In vivo, claudin-4 positive tumour xenografts, endogenous pancreatic tumours, hepatic metastases, as well as preinvasive PanIN lesions, were visualised by FRI and FMT up to 48 h after injection showing a significantly higher average of fluorochrome concentration as compared with claudin-4 negative xenografts and normal pancreatic tissue. CONCLUSIONS: C-CPE-Cy5.5 combined with novel optical imaging methods enables non-invasive visualisation of claudin-4 positive murine pancreatic tumours and their precursor lesions, representing a promising modality for early diagnostic imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2012-302577

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 77

Metadata

Authors
Neesse, A., Hahnenkamp, A., Griesmann, H., Buchholz, M., Hahn, S. A., Maghnouj, A., Fendrich, V., Ring, J., Sipos, B., Tuveson, D. A., Bremer, C., Gress, T. M., & Michl, P.
Venue
Gut
Publisher
BMJ
Published
2012-06-07
Volume
62
Issue
7
Pages
1034-1043
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2123144110
Cited by
77
References
3
FWCI
4.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Claudin-4-targeted optical imaging detects pancreatic cancer and its precursor lesions. https://app.cochat.ai/papers/10.1136/gutjnl-2012-302577
The paper
Neesse, A., Hahnenkamp, A., Griesmann, H., Buchholz, M., Hahn, S. A., Maghnouj, A., Fendrich, V., Ring, J., Sipos, B., Tuveson, D. A., Bremer, C., Gress, T. M., & Michl, P. (2013). Claudin-4-targeted optical imaging detects pancreatic cancer and its precursor lesions. Gut. https://doi.org/10.1136/gutjnl-2012-302577

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.