CoChat

Estimating the environmental impact of disposable endoscopic equipment and endoscopes

Namburar, Sathvik, von Renteln, Daniel, Damianos, John, Bradish, Lisa, Barrett, Jeanne, Aguilera-Fish, Andres, Cushman-Roisin, Benoit, Pohl, Heiko · 2022 · Gut
Cited by 171

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Objective: Procedure-intense specialties, such as surgery or endoscopy, are a major contributor to the impact of the healthcare sector on the environment. We aimed to measure the amount of waste generated during endoscopic procedures and to understand the impact on waste of changing from reusable to single use endoscopes in the USA. Design: We conducted a 5-day audit (cross-sectional study) of all endoscopies performed at two US academic medical centres with low and a high endoscopy volume (2000 and 13 000 procedures annually, respectively). We calculated the average disposable waste (excluding waste from reprocessing) generated during one endoscopic procedure to estimate waste of all endoscopic procedures generated in the USA annually (18 million). We further estimated the impact of changing from reusable to single-use endoscopes taking reprocessing waste into account. Results: 278 endoscopies were performed for 243 patients. Each endoscopy generated 2.1 kg of disposable waste (46 L volume). 64% of waste was going to the landfill, 28% represented biohazard waste and 9% was recycled. The estimated total waste generated during all endoscopic procedures performed in the USA annually would weigh 38 000 metric tons (equivalent of 25 000 passenger cars) and cover 117 soccer fields to 1 m depth. If all endoscopic procedures were performed with single-use endoscopes and accounting for reprocessing, the net waste mass would increase by 40%. Excluding waste from ancillary supplies, net waste generated from reprocessing and endoscope disposal would quadruple with only using single-use endoscopes. Conclusion: This quantitative assessment of the environmental impact of endoscopic procedures highlights that a large amount of waste is generated from disposable instruments. Transitioning to single-use endoscopes may reduce reprocessing waste but would increase net waste.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2021-324729

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Metadata

Authors
Namburar, S., von Renteln, D., Damianos, J., Bradish, L., Barrett, J., Aguilera-Fish, A., Cushman-Roisin, B., & Pohl, H.
Venue
Gut
Publisher
BMJ
Published
2021-12-01
Volume
71
Issue
7
Pages
1326-1331
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W3216922782
Cited by
171
References
8
FWCI
20.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating the environmental impact of disposable endoscopic equipment and endoscopes. https://app.cochat.ai/papers/10.1136/gutjnl-2021-324729
The paper
Namburar, S., von Renteln, D., Damianos, J., Bradish, L., Barrett, J., Aguilera-Fish, A., Cushman-Roisin, B., & Pohl, H. (2022). Estimating the environmental impact of disposable endoscopic equipment and endoscopes. Gut. https://doi.org/10.1136/gutjnl-2021-324729

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.