Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography

Open access
Ionescu, A, Fraser, A G, Butchart, E G·2003·Heart

Abstract

Objective: To assess the prevalence, mechanisms, and significance of paraprosthetic regurgitation detected incidentally by transoesophageal echocardiography (TOE) in patients after heart valve replacement. Design: Prospective observational study. Setting: Tertiary referral centre. Patients: 360 consecutive patients (mean (SD) age 65.8(9.5) years, 193 women) undergoing elective first ever valve replacement. Methods: Postoperative and follow up TOE, and tests for haemolysis and anaemia. Results: There were 243 aortic, 90 mitral, and 27 double valve replacements, using 316 mechanical and 44 tissue valves, giving 270 aortic and 117 mitral valves. One patient with severe paraprosthetic mitral regurgitation underwent immediate reoperation and was excluded from subsequent analyses. Paraprosthetic jets were detected around 16 (6%) of the aortic and 38 (32%) of the mitral valves (p < 0.05) at the postoperative study. Follow up TOE was available for 151 aortic and 67 mitral valves, 0.9 (0.5) years after operation. Paraprosthetic jets were present in 15 (10%) of the aortic and 10 (15%) of the mitral valves (NS). Two thirds of the aortic and a fifth of the mitral jets were new. Paraprosthetic jets were more common in aortic valves in a supra-annular (12 of 88, 14%) than in an intra-annular position (4 or 182, 2%; p < 0.005) and in mitral valves inserted with continuous (36 of 88, 41%) rather than interrupted sutures (2 of 28, 7%; p < 0.001). Lactate dehydrogenase concentration was higher in patients with paraprosthetic jets than in those without (752 (236) v 654 (208) IU/l, p < 0.001). Haemoglobin and haptoglobin concentrations were not different. Conclusions: Small paraprosthetic leaks are common, are related to surgical factors, are not associated with increased subclinical haemolysis, and are benign during the first year after heart valve replacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heart.89.11.1316

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 324

Metadata

Authors
Ionescu, A., Fraser, A. G., & Butchart, E. G.
Venue
Heart
Publisher
BMJ
Published
2003-10-31
Volume
89
Issue
11
Pages
1316-1321
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2062790358
Cited by
324
References
9
FWCI
0.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography. https://app.cochat.ai/papers/10.1136/heart.89.11.1316
The paper
Ionescu, A., Fraser, A. G., & Butchart, E. G. (2003). Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography. Heart. https://doi.org/10.1136/heart.89.11.1316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.