The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Open accessAbstract
Objectives: To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Methods: Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). Results: No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Conclusion: Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trace Elements in Human and Animal Nutrition
UNDERWOOD, E. J. (1963) · Soil Science · doi:10.1097/00010694-196304000-00029 · Cited by 4,507
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Trace Elements in Human and Animal Nutrition
UNDERWOOD, E. J. (1956) · Soil Science · doi:10.1097/00010694-195611000-00018 · Cited by 970
Pathology of Acute and Chronic Coronary Stenting in Humans
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R. (1999) · Circulation · doi:10.1161/01.cir.99.1.44 · Cited by 871
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Kornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Lincoff, A. M., Furst, J. G., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282
Biodegradable Stents: “Fulfilling the Mission and Stepping Away”
Colombo, A., & Karvouni, E. (2000) · Circulation · doi:10.1161/01.cir.102.4.371 · Cited by 182
Cheng, G. C., Briggs, W. H., Gerson, D. S., Libby, P., Grodzinsky, A. J., Gray, M. L., & Lee, R. T. (1997) · Circulation Research · doi:10.1161/01.res.80.1.28 · Cited by 161
Review of corrosion and corrosion control of magnesium alloys and composites
Ferrando, W. A. (1989) · Journal of Materials Engineering · doi:10.1007/bf02834140 · Cited by 125
Theoretical and practical aspects of testing potential biomaterialsin vitro
Kirkpatrick, C. J., & Mittermayer, C. (1990) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00705347 · Cited by 119
Role of polymers in improving the results of stenting in coronary arteries
Peng, T. (1996) · Biomaterials · doi:10.1016/0142-9612(96)86738-x · Cited by 118
Inhibition of Neointima Formation After Experimental Coronary Artery Stenting
Alt, E., Hähnel, I., Beilharz, C., Prietzel, K., Preter, D., Stemberger, A., Fliedner, T., Erhardt, W. D., & Schömig, A. (2000) · Circulation · doi:10.1161/01.cir.101.12.1453 · Cited by 98
Schwartz, R. S., Edwards, W. D., Bailey, K. R., Camrud, A. R., Jorgenson, M., & Holmes, D. R. (1994) · Arteriosclerosis and Thrombosis A Journal of Vascular Biology · doi:10.1161/01.atv.14.3.395 · Cited by 97
Initial and 6-Month Results of Biodegradable Poly-l-Lactic Acid Coronary Stents in Humans
HideoTamai, KeijiIgaki, EishoKyo, KunihikoKosuga, AkiyoshiKawashima, ShigeoMatsui, HidenoriKomori, TakafumiTsuji, SeiichiroMotohara, & HiromuUehata (2000) · Circulation · Cited by 56
Local methylprednisolone inhibition of foreign body response to coated intracoronary stents
Scheerder, I. D., Wang, K., Wilczek, K., van Dorpe, J., Verbeken, E. K., Desmet, W., Schacht, E. H., & Piessens, J. (1996) · Coronary Artery Disease · doi:10.1097/00019501-199602000-00011 · Cited by 52
Biomaterialien – humane Toleranz und Integration
Wintermantel, E., Mayer, J., Ruffieux, K., Bruinink, A., & Eckert, K.-L. (1999) · Der Chirurg · doi:10.1007/s001040050734 · Cited by 38
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
Fundamentals and advances in magnesium alloy corrosion
Esmaily, M., Svensson, J. E., Fajardo, S., Birbilis, N., Frankel, G. S., Virtanen, S., Arrabal, R., Thomas, S., & Johansson, L. G. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.011 · Cited by 2,073
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Metadata
- Authors
- Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2003-06
- Volume
- 89
- Issue
- 6
- Pages
- 651-656
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2128126525
- Cited by
- 806
- References
- 18
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.