CoChat

Predictors of clinical efficacy of ‘Ablate and Pace’ therapy in patients with permanent atrial fibrillation

Brignole, M, Botto, G L, Mont, L, Oddone, D, Iacopino, S, De Marchi, G, Campoli, M, Sebastiani, V, Vincenti, A, Garcia Medina, D, Osca Asensi, J, Mocini, A, Grovale, N, De Santo, T, Menozzi, C · 2012 · Heart
Cited by 46

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: To evaluate the 2-year clinical improvement after 'Ablate and Pace' therapy and to identify the variables able to influence the efficacy of this therapy in patients with permanent atrial fibrillation (AF). Design: Prospective multicentre observational study. Setting: Cardiology departments of 19 general hospitals in Italy, Spain and Greece. Patients: 171 patients with drug-refractory severely symptomatic permanent AF considered for AV junction ablation. Interventions: Patients underwent AV junction ablation, received a right ventricular (RV) pacing or echo-guided cardiac resynchronisation (CRT) pacing and were followed-up to 24 months. Main outcome measures: Non-responders to Ablate and Pace therapy were defined those patients who, during the follow-up period had clinical failure (defined as death or hospitalisation due to heart failure, or worsening heart failure) or showed no improvement in their clinical condition. Results: Responders were 63% of RV-paced patients and 83% of CRT-paced patients. Another 27% showed no clinical improvement (7%) or worsened (20%) (non-responders group). On multivariable Cox regression analysis, CRT mode and echo-optimised CRT were the only independent protective factors against non-response (HR=0.24, 95% CI 0.10–0.58, p=0.001 and HR=0.22, 95% CI 0.07–0.77, p=0.018 respectively). On comparing freedom from non-response, a trend in favour of echo-optimised CRT versus simultaneous biventricular pacing (p=0.077) was seen. Conclusions: In patients affected by severely symptomatic permanent AF, Ablate and Pace therapy yielded a clinical benefit in 63% of RV-paced patients and 83% of CRT-paced patients. CRT pacing and echo-optimised CRT were the only independent predictor of clinical benefit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2011-301069

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 46

Metadata

Authors
Brignole, M., Botto, G. L., Mont, L., Oddone, D., Iacopino, S., De Marchi, G., Campoli, M., Sebastiani, V, Vincenti, A., Garcia Medina, D., Osca Asensi, J., Mocini, A., Grovale, N., De Santo, T., & Menozzi, C.
Venue
Heart
Publisher
BMJ
Published
2011-11-17
Volume
98
Issue
4
Pages
297-302
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2096778183
Cited by
46
References
2
FWCI
5.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictors of clinical efficacy of ‘Ablate and Pace’ therapy in patients with permanent atrial fibrillation. https://app.cochat.ai/papers/10.1136/heartjnl-2011-301069
The paper
Brignole, M., Botto, G. L., Mont, L., Oddone, D., Iacopino, S., De Marchi, G., Campoli, M., Sebastiani, V, Vincenti, A., Garcia Medina, D., Osca Asensi, J., Mocini, A., Grovale, N., De Santo, T., & Menozzi, C. (2012). Predictors of clinical efficacy of ‘Ablate and Pace’ therapy in patients with permanent atrial fibrillation. Heart. https://doi.org/10.1136/heartjnl-2011-301069

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.