CoChat

RV-pulmonary arterial coupling predicts outcome in patients referred for pulmonary hypertension

Open access
Vanderpool, Rebecca R, Pinsky, Michael R, Naeije, Robert, Deible, Christopher, Kosaraju, Vijaya, Bunner, Cheryl, Mathier, Michael A, Lacomis, Joan, Champion, Hunter C, Simon, Marc A · 2015 · Heart
Cited by 354

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Objective: Prognosis in pulmonary hypertension (PH) is largely determined by RV function. However, uncertainty remains about what metrics of RV function might be most clinically relevant. The purpose of this study was to assess the clinical relevance of metrics of RV functional adaptation to increased afterload. Methods: Patients referred for PH underwent right heart catheterisation and RV volumetric assessment within 48 h. A RV maximum pressure (Pmax) was calculated from the RV pressure curve. The adequacy of RV systolic functional adaptation to increased afterload was estimated either by a stroke volume (SV)/end-systolic volume (ESV) ratio, a Pmax/mean pulmonary artery pressure (mPAP) ratio, or by EF (RVEF). Diastolic function of the RV was estimated by a diastolic elastance coefficient β. Survival analysis was via Cox proportional HR, and Kaplan–Meier with the primary outcome of time to death or lung transplant. Results: Patients (n=50; age 58±13 yrs) covered a range of mPAP (13–79 mm Hg) with an average RVEF of 39±17% and ESV of 143±89 mL. Average estimates of the ratio of end-systolic ventricular to arterial elastance were 0.79±0.67 (SV/ESV) and 2.3±0.65 (Pmax/mPAP-1). Transplantation-free survival was predicted by right atrial pressure, mPAP, pulmonary vascular resistance, β, SV, ESV, SV/ESV and RVEF, but after controlling for right atrial pressure, mPAP, and SV, SV/ESV was the only independent predictor. Conclusions: The adequacy of RV functional adaptation to afterload predicts survival in patients referred for PH. Whether this can simply be evaluated using RV volumetric imaging will require additional confirmation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2014-306142

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 354

Metadata

Authors
Vanderpool, R. R., Pinsky, M. R., Naeije, R., Deible, C., Kosaraju, V., Bunner, C., Mathier, M. A., Lacomis, J., Champion, H. C., & Simon, M. A.
Venue
Heart
Publisher
BMJ
Published
2014-09-11
Volume
101
Issue
1
Pages
37-43
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2119487317
Cited by
354
References
20
FWCI
16.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.