Instantaneous pressure-volume relationship of the canine right ventricle.

Maughan, W L, Shoukas, A A, Sagawa, K, Weisfeldt, M L·1979·Circulation Research

Abstract

The instantaneous isovolumic and ejecting pressure-volume relationship of the right ventricle was studied in 11 cross-circulated, isolated canine hearts to characterize the right ventricular contractile state.Accurate measurement of volume was achieved by the use of a water-filled, thin latex balloon in the right ventricle connected to a special volume loading and transducing chamber.Pressure was measured with a miniature pressure transducer mounted within the balloon.Wide variations in loading conditions were achieved by changing the volume of air above the volumetric chamber.The pressure and volume data were collected from multiple beats under a constant contractile state in the same mode of contraction while the left ventricle was vented to air.Linear regression analysis applied to each of the isochronal pressure-volume data sets at 20-msec intervals from the onset of contraction showed a highly linear correlation between the pressure and the volume.Both the slope and the volume intercept of the regression lines changed with time throughout the cardiac cycle.The maximal slope of the regression line (E,,,,) averaged 2.50 ± 0.49 mm Hg/ml (mean ± SD) for ejecting beats and 2.68 ± 0.55 mm Hg/ml for isovolumic beats.Epinephrine infusions of 12.5 fig/min and 25.0 /ig/min increased E^u by 31% and 82%, respectively (P < 0.005).We conclude that: (1) The instantaneous pressure-volume relationships of the right ventricle in the isovolumic and ejecting modes can be regarded as linear, at least within the physiological range; however, these two modes of contraction did not yield an identical relationship.(2) The slope of these pressure-volume relationship curves changes with a change in the contractile state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.44.3.309

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 313

Metadata

Authors
Maughan, W. L., Shoukas, A. A., Sagawa, K., & Weisfeldt, M. L.
Venue
Circulation Research
Published
1979-03
Volume
44
Issue
3
Pages
309-315
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2074374690
Cited by
313
References
6
FWCI
5.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Instantaneous pressure-volume relationship of the canine right ventricle. https://app.cochat.ai/papers/10.1161/01.res.44.3.309
The paper
Maughan, W. L., Shoukas, A. A., Sagawa, K., & Weisfeldt, M. L. (1979). Instantaneous pressure-volume relationship of the canine right ventricle. Circulation Research. https://doi.org/10.1161/01.res.44.3.309

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.