CoChat

Non-ischaemic cardiomyopathy, sudden death and implantable defibrillators: a review and meta-analysis

Open access
Beggs, Simon A S, Jhund, Pardeep S, Jackson, Colette E, McMurray, John J V, Gardner, Roy S · 2018 · Heart
Cited by 90

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Objective: The recent Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) trial suggested that implantable cardioverter defibrillators (ICDs) do not reduce overall mortality in patients with non-ischaemic cardiomyopathy (NICM), despite reducing sudden cardiac death. We performed an updated meta-analysis to examine the impact of ICD therapy on mortality in NICM patients. Methods: A systematic search for studies that examined the effect of ICDs on outcomes in NICM was performed. Our analysis compared patients randomised to an ICD with those randomised to no ICD, and examined the endpoint of overall mortality. Results: Six primary prevention trials and two secondary prevention trials were identified that met the pre-specified search criteria. Using a fixed-effects model, analysis of primary prevention trials revealed a reduction in overall mortality with ICD therapy (RR 0.76, 95% CI 0.65 to 0.91). Conclusions: Although our updated meta-analysis demonstrates a survival benefit of ICD therapy, the effect is substantively weakened by the inclusion of the DANISH trial—which is both the largest and most recent of the analysed trials—indicating that the residual pooled benefit of ICDs may reflect the risk of sudden death in older trials which included patients treated sub-optimally by contemporary standards. As such, these data must be interpreted cautiously. The results of the DANISH trial emphasise that there is no ‘one size fits all’ indication for primary prevention ICDs in NICM patients, and clinicians must consider age and comorbidity on an individual basis when determining whether a defibrillator is appropriate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2016-310850

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 90

Metadata

Authors
Beggs, S. A. S., Jhund, P. S., Jackson, C. E., McMurray, J. J. V., & Gardner, R. S.
Venue
Heart
Publisher
BMJ
Published
2017-10-06
Volume
104
Issue
2
Pages
144-150
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2756166241
Cited by
90
References
8
FWCI
3.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-ischaemic cardiomyopathy, sudden death and implantable defibrillators: a review and meta-analysis. https://app.cochat.ai/papers/10.1136/heartjnl-2016-310850
The paper
Beggs, S. A. S., Jhund, P. S., Jackson, C. E., McMurray, J. J. V., & Gardner, R. S. (2018). Non-ischaemic cardiomyopathy, sudden death and implantable defibrillators: a review and meta-analysis. Heart. https://doi.org/10.1136/heartjnl-2016-310850

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.