The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis
Abstract
Context: Coronary artery disease (CAD) is a major cause of mortality and ill health. Objective: To assess whether 64-slice CT angiography might replace some coronary angiography (CA) for diagnosis and assessment of CAD. Data sources: Electronic databases, conference proceedings and reference lists of included studies. Study selection: Eligible studies compared 64-slice CT with a reference standard of CA in adults with suspected/known CAD, reporting sensitivity and specificity or true and false positives and negatives. Data extraction: Two reviewers independently extracted data from included studies. Results: Forty studies were included; 28 provided sufficient data for inclusion in the meta-analyses, all using a cut off point of ⩾50% stenosis to define significant CAD. In patient-based detection (n = 1286) 64-slice CT pooled sensitivity was 99% (95% credible interval (CrI) 97% to 99%), specificity 89% (95% CrI 83% to 94%), median positive predictive value (PPV) across studies 93% (range 64–100%) and negative predictive value (NPV) 100% (range 86–100%). In segment-based detection (n = 14 199) 64-slice CT pooled sensitivity was 90% (95% CrI 85% to 94%), specificity 97% (95% CrI 95% to 98%), median PPV across studies 76% (range 44–93%) and NPV 99% (range 95–100%). Conclusions: 64-Slice CT is highly sensitive for patient-based detection of CAD and has high NPV. An ability to rule out significant CAD means that it may have a role in the assessment of chest pain, particularly when the diagnosis remains uncertain despite clinical evaluation and simple non-invasive testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cochrane Handbook for Systematic Reviews of Interventions: Cochrane Book Series
(2008) · doi:10.1002/9780470712184 · Cited by 25,048
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Goldstein, J. A., Chinnaiyan, K. M., Abidov, A., Achenbach, S., Berman, D. S., Hayes, S. W., Hoffmann, U., Lesser, J. R., Mikati, I. A., O'Neil, B. J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.03.068 · Cited by 583
Prognostic Value of Cardiac Computed Tomography Angiography
Hulten, E. A., Carbonaro, S., Petrillo, S. P., Mitchell, J. D., & Villines, T. C. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.011 · Cited by 412
Metadata
- Authors
- Mowatt, G., Cook, J. A., Hillis, G. S., Walker, S., Fraser, C., Jia, X., & Waugh, N.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2008-07-31
- Volume
- 94
- Issue
- 11
- Pages
- 1386-1393
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2110119301
- Cited by
- 484
- References
- 23
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. https://app.cochat.ai/papers/10.1136/hrt.2008.145292
- The paper
- Mowatt, G., Cook, J. A., Hillis, G. S., Walker, S., Fraser, C., Jia, X., & Waugh, N. (2008). 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart. https://doi.org/10.1136/hrt.2008.145292
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.