The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
Open accessAbstract
Objective: To investigate the performance of low-dose, dual-source computed tomography (DSCT) coronary angiography in the step-and-shoot (SAS) mode for the diagnosis of significant coronary artery stenoses in comparison with conventional coronary angiography (CCA). Design, setting and patients: Prospective, single-centre study conducted in a referral centre enrolling 120 patients (71 men, mean (SD) age 68 (9) years, mean (SD) body mass index 26.2 (3.2) kg/m2). All study participants underwent DSCT in the SAS mode and CCA within 14 days. Twenty-seven patients were given intravenous β blockers for heart rate reduction before CT. Patients were excluded if a target heart rate ⩽70 bpm could not be achieved by β blockers or when the patients were in non-sinus rhythm. Two blinded readers independently evaluated coronary artery segments for assessability and for the presence of significant (>50%) stenoses. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) were determined, with CCA being the standard of reference. Radiation dose values were calculated. Results: DSCT coronary angiography in the SAS mode was successfully performed in all 120 patients. Mean (SD) heart rate during scanning was 59 (6) bpm (range 44–69). 1773/1803 coronary segments (98%) were depicted with a diagnostic image quality in 109/120 patients (91%). The overall patient-based sensitivity, specificity, PPV and NPV for the diagnosis of significant stenoses were 100%, 93%, 94% and 100%, respectively. The mean (SD) effective dose of the CT protocol was 2.5 (0.8) mSv (range 1.2–4.4). Conclusions: DSCT coronary angiography in the SAS mode allows, in selected patients with a regular heart rate, the accurate diagnosis of significant coronary stenoses at a low radiation dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.
Diamond, G. A., & Forrester, J. S. (1979) · New England Journal of Medicine · doi:10.1056/nejm197906143002402 · Cited by 2,664
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Self-citationHausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Cited by
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Achenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Metadata
- Authors
- Scheffel, H., Alkadhi, H., Leschka, S., Plass, A., Desbiolles, L., Guber, I., Krauss, T., Gruenenfelder, J., Genoni, M., Luescher, T. F., Marincek, B., & Stolzmann, P.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2008-06-02
- Volume
- 94
- Issue
- 9
- Pages
- 1132-1137
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2105778334
- Cited by
- 291
- References
- 23
- FWCI
- 45.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. https://app.cochat.ai/papers/10.1136/hrt.2008.149971
- The paper
- Scheffel, H., Alkadhi, H., Leschka, S., Plass, A., Desbiolles, L., Guber, I., Krauss, T., Gruenenfelder, J., Genoni, M., Luescher, T. F., Marincek, B., & Stolzmann, P. (2008). Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart. https://doi.org/10.1136/hrt.2008.149971
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.