The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy
Abstract
Background: Although the benefit of implantable cardioverter defibrillator (ICD) therapy in patients with hypertrophic cardiomyopathy (HCM) at risk for sudden cardiac arrest is well established, there may be a higher risk for device complications and inappropriate shocks. Objectives: To determine the incidence of inappropriate ICD shocks and device complications in HCM patients and the impact of young age at ICD implant and atrial fibrillation. Methods: HCM patients who underwent ICD implantation between January 1988 and December 2005 were included. The frequency of device complications, including pneumothorax, pericardial effusion, haematoma, lead revisions, infection and rate of inappropriate shocks, was determined. ICD shocks were characterised as inappropriate if triggered by sinus tachycardia, atrial fibrillation or device malfunction. Results: A total of 181 patients were included (mean age 44 (SD 17) years; 62% males). During a mean follow-up of 59 (42) months (4.92 years; 830.75 patient-years), 65 patients (36%) had a total of 88 device complications, including 42 (23%) patients with inappropriate shocks. The rate of inappropriate shocks was 5.3% per year (vs 4% risk of appropriate shocks), and the likelihood of inappropriate ICD shocks per 100 patient-years was 5.1. Younger age and atrial fibrillation were associated with an increased risk of inappropriate ICD discharges. Conclusions: The rate of inappropriate ICD shocks and frequency of device complications in HCM patients are not insignificant and are most common in younger patients and those with atrial fibrillation. Inappropriate ICD shocks are the most common device complication and should be accounted for when counselling high-risk HCM patients for ICD implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Cited by
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318223e2bd · Cited by 2,104
Self-citation2011 ACCF/AHA Guideline for the Diagnosis and Treatment of Hypertrophic Cardiomyopathy
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.011 · Cited by 1,276
Self-citationGersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318223e230 · Cited by 818
Self-citation
Metadata
- Authors
- Lin, G., Nishimura, R. A., Gersh, B. J., Phil, D., Ommen, S. R., Ackerman, M. J., & Brady, P. A.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2009-03-11
- Volume
- 95
- Issue
- 9
- Pages
- 709-714
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2115309846
- Cited by
- 158
- References
- 2
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy. https://app.cochat.ai/papers/10.1136/hrt.2008.150656
- The paper
- Lin, G., Nishimura, R. A., Gersh, B. J., Phil, D., Ommen, S. R., Ackerman, M. J., & Brady, P. A. (2009). Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy. Heart. https://doi.org/10.1136/hrt.2008.150656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).