Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 234

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Risk factors and time delay associated with cardiac device infections: Leiden device registry

Lekkerkerker, J C, van Nieuwkoop, C, Trines, S A, van der Bom, J G, Bernards, A, van de Velde, E T, Bootsma, M, Zeppenfeld, K, Jukema, J W, Borleffs, J-W, Schalij, M J, van Erven, L · 2009 · Heart

Abstract

Aims: A nested case-control study of 75 patients with cardiac device infections (CDI) and 75 matched controls was conducted to evaluate time course, risk factors, culture results and frequency of CDI. Methods and results: CDI occurred in 75/3410 (2.2%) device implantation and revision procedures, performed between 2000 and 2007. The time delay between device procedure and infection ranged from 0 to 64 months (mean 14 (SD 16)), 21 patients (28%) had an early infection (<1 month), 26 (35%) a late infection (1–12 months) and 28 (37%) a delayed infection (>12 months). Of interest, 18 (24%) patients presented with an infection >24 months after the device-related procedure. Time delay until infection was significantly shorter when cultures were positive for micro-organisms compared to negative cultures (8 (12) vs 18 (18) months, p = 0.03). Pocket cultures in delayed infections remained more often negative (61% vs 23%, p = 0.01). Independent CDI risk factors were: device revision (odds ratio (OR) 3.67; 95% confidence interval (CI), 1.51 to 8.96), renal dysfunction defined as glomerular filtration rate <60 ml/min (OR 4.64; CI, 1.48 to 14.62) and oral anticoagulation use (OR 2.83; CI 1.20 to 6.68). Conclusion: CDI occurred in 2.2% of device procedures, with 24% occurring more than two years after the device-related procedure. Renal dysfunction, device revisions and oral anticoagulation are potent risk factors for CDI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.2008.151985

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 234

Metadata

Authors
Lekkerkerker, J. C., van Nieuwkoop, C., Trines, S. A., van der Bom, J. G., Bernards, A., van de Velde, E. T., Bootsma, M., Zeppenfeld, K., Jukema, J. W., Borleffs, J.-W., Schalij, M. J., & van Erven, L.
Venue
Heart
Publisher
BMJ
Published
2008-11-26
Volume
95
Issue
9
Pages
715-720
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2150608978
Cited by
234
References
1
FWCI
5.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk factors and time delay associated with cardiac device infections: Leiden device registry. https://app.cochat.ai/papers/10.1136/hrt.2008.151985
The paper
Lekkerkerker, J. C., van Nieuwkoop, C., Trines, S. A., van der Bom, J. G., Bernards, A., van de Velde, E. T., Bootsma, M., Zeppenfeld, K., Jukema, J. W., Borleffs, J.-W., Schalij, M. J., & van Erven, L. (2009). Risk factors and time delay associated with cardiac device infections: Leiden device registry. Heart. https://doi.org/10.1136/hrt.2008.151985

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.