Risk factors and time delay associated with cardiac device infections: Leiden device registry
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Aims: A nested case-control study of 75 patients with cardiac device infections (CDI) and 75 matched controls was conducted to evaluate time course, risk factors, culture results and frequency of CDI. Methods and results: CDI occurred in 75/3410 (2.2%) device implantation and revision procedures, performed between 2000 and 2007. The time delay between device procedure and infection ranged from 0 to 64 months (mean 14 (SD 16)), 21 patients (28%) had an early infection (<1 month), 26 (35%) a late infection (1–12 months) and 28 (37%) a delayed infection (>12 months). Of interest, 18 (24%) patients presented with an infection >24 months after the device-related procedure. Time delay until infection was significantly shorter when cultures were positive for micro-organisms compared to negative cultures (8 (12) vs 18 (18) months, p = 0.03). Pocket cultures in delayed infections remained more often negative (61% vs 23%, p = 0.01). Independent CDI risk factors were: device revision (odds ratio (OR) 3.67; 95% confidence interval (CI), 1.51 to 8.96), renal dysfunction defined as glomerular filtration rate <60 ml/min (OR 4.64; CI, 1.48 to 14.62) and oral anticoagulation use (OR 2.83; CI 1.20 to 6.68). Conclusion: CDI occurred in 2.2% of device procedures, with 24% occurring more than two years after the device-related procedure. Renal dysfunction, device revisions and oral anticoagulation are potent risk factors for CDI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Treatment of Infections Associated with Surgical Implants
Darouiche, R. O. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035415 · Cited by 2,257
Bax, J. J., Bleeker, G. B., Marwick, T. H., Molhoek, S. G., Boersma, E., Steendijk, P., van der Wall, E. E., & Schalij, M. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.016 · Cited by 1,062
Self-citationManagement and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection: A Population-Based Study
Uslan, D. Z. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.7.669 · Cited by 391
Chamis, A. L., Peterson, G. E., Cabell, C. H., Corey, G. R., Sorrentino, R. A., Greenfield, R. A., Ryan, T., Reller, L. B., & Fowler, V. G. (2001) · Circulation · doi:10.1161/hc3401.095097 · Cited by 292
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Habib, G., Lancellotti, P., Antunes, M. J., Bongiorni, M. G., Casalta, J.-P., Del Zotti, F., Dulgheru, R., El Khoury, G., Erba, P. A., Iung, B., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv319 · Cited by 4,997
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Sandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Clinically Significant Pocket Hematoma Increases Long-Term Risk of Device Infection
Essebag, V., Verma, A., Healey, J. S., Krahn, A. D., Kalfon, E., Coutu, B., Ayala-Paredes, F., Tang, A. S., Sapp, J., Sturmer, M., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.01.009 · Cited by 201
Juneau, D., Golfam, M., Hazra, S., Zuckier, L. S., Garas, S., Redpath, C., Bernick, J., Leung, E., Chih, S., Wells, G., et al. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.116.005772 · Cited by 160
Lin, Y.-S., Hung, S.-P., Chen, P.-R., Yang, C.-H., Wo, H.-T., Chang, P.-C., Wang, C.-C., Chou, C.-C., Wen, M.-S., Chung, C.-M., et al. (2014) · Medicine · doi:10.1097/md.0000000000000213 · Cited by 58
Endovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
Metadata
- Authors
- Lekkerkerker, J. C., van Nieuwkoop, C., Trines, S. A., van der Bom, J. G., Bernards, A., van de Velde, E. T., Bootsma, M., Zeppenfeld, K., Jukema, J. W., Borleffs, J.-W., Schalij, M. J., & van Erven, L.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2008-11-26
- Volume
- 95
- Issue
- 9
- Pages
- 715-720
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2150608978
- Cited by
- 234
- References
- 20
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.