The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
CARDIAC OUTPUT IN MAN BY A DIRECT FICK METHOD: Effects of Posture, Venous Pressure Change, Atropine, And Adrenaline
Open accessAbstract
In the Fick method of estimating cardiac output (C.O.), where C.O. (litres/min.)=oxygenconsumption (c.c./min.)divided by arterio-venous oxygen difference (c.c./litre), the measure- ment of the numerator can easily be made by spirometric methods.Hitherto the measurement of the arterio-venous oxygen difference in man by respiratory techniques has proved difficult and laborious, and it has not been possible to make frequent serial observations.The difficulties seem to be largely overcome by the method of cardiac catheterization first introduced by Forsmann (1929) and developed by Cournand and Ranges (1941).Over 394 catheterizations can now be recorded without any accidents (Forsmann (1), de Carvolho and Moniz (48), Ameuille et al. (60+), Cournand et al. ( 150) and the present authors ( 135)).The catheter has been left in situ as long as 24 hours (Cournand et al.), but the present authors have limited the period to one hour in normal subjects.Clotting does not occur on the unwettable surface of the catheter, and a slow drip of 3-8 per cent sodium citrate through the catheter prevents any thrombus formation round the hole at the tip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Catheterization of the Right Auricle in Man
Cournand, A., & Ranges, H. A. (1941) · Experimental Biology and Medicine · doi:10.3181/00379727-46-12029 · Cited by 450
PHYSIOLOGICAL STUDY OF THE VERTICAL STANCE OF MAN
Hellebrandt, F. A., & Brogdon, E. (1943) · Physiological Reviews · doi:10.1152/physrev.1943.23.3.220 · Cited by 85
The relation between heart volume and stroke volume in recumbent and erect positions1
Nylin, G. (1934) · Skandinavisches Archiv Für Physiologie · doi:10.1111/j.1748-1716.1934.tb01099.x · Cited by 70
BLOOD CHANGES FOLLOWING CONTROLLED HqMORRHAGE IN MAN
Wallace, J. (1941) · The Lancet · doi:10.1016/s0140-6736(00)76528-7 · Cited by 67
Richards, D. W., Cournand, A. F., Darling, R. C., Gillespie, W. H., & Baldwin, E. D. (1942) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1942.136.1.115 · Cited by 51
Cited by
HEAD-UP TILT: A USEFUL TEST FOR INVESTIGATING UNEXPLAINED SYNCOPE
Anne Kenny, R., Bayliss, J., Ingram, A., & Sutton, R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)91665-x · Cited by 781
Goldenberg, M., Pines, K. L., de F. Baldwin, E., Greene, D. G., & Roh, C. E. (1948) · The American Journal of Medicine · doi:10.1016/0002-9343(48)90158-2 · Cited by 455
Bevegård, S., Holmgren, A., & Jonsson, B. (1960) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1960.tb01953.x · Cited by 443
Methodology of head-up tilt testing in patients with unexplained syncope
Fitzpatrick, A. P., Theodorakis, G., Vardas, P., & Sutton, R. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90714-k · Cited by 432
Mechanisms of Contraction of the Normal and Failing Heart.
(1976) · Annals of Internal Medicine · doi:10.7326/0003-4819-85-3-413_3 · Cited by 366
Metadata
- Authors
- McMichael, J., & Sharpey-Schafer, E. P.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1944-01-01
- Volume
- 6
- Issue
- 1
- Pages
- 33-40
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2150162698
- Cited by
- 276
- References
- 5
- FWCI
- 27.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.