Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objectives: To increase awareness of the potential for disabling anxiety and depression in patients receiving shocks from implanted cardioverter-defibrillators (ICDs). Patients and methods: ICDs are implanted in patients at this hospital for control of serious ventricular tachyarrhythmias inadequately controlled by drug treatment, who are unsuitable for map guided antiarrhythmic surgery. All are reviewed regularly at a dedicated ICD clinic and are advised to make contact between visits if they experience shocks. Symptoms of anxiety or depression were not actively sought, nor was a patient support group operating at the time of this data collection. When overt psychopathology was identified, patients were referred to a designated psychiatrist for management. Results: Over a six year period, six (17%) of 35 patients with ICDs developed florid psychiatric problems after experiencing shocks. None had premorbid psychiatric predisposition. Of the six patients suffering severe psychiatric problems, four were men, their age range was 30–63 years, and left ventricular ejection fraction was 18–40%. All shocks were appropriate for clinical arrhythmias and ranged in frequency from two in six months to 111 in 24 hours. All six patients manifested severe anxiety, focused on fear of future shocks. Depression was also evident in three patients and two had become housebound. All responded within weeks to anxiolytic or antidepressant drugs, combined with relaxation and cognitive therapies. Ongoing psychiatric therapy was refused by one patient, and was required for between three and 18 months in the remainder. One patient died and one received a cardiac transplant during the follow up period (median 27.5 months, range 8–43). Conclusions: Because ICD implantation occurs against a complex medical background with inevitable psychological stress, all such patients should be considered at high risk for developing psychopathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clark, D. M. (1986) · Behaviour Research and Therapy · doi:10.1016/0005-7967(86)90011-2 · Cited by 2,422 · cited 1×
“One dominant thought pattern was identified in all six patients in this group: “If the device fires I’m going to die”. This catastrophic thought about the purpose of the device fed straight into the panic cycle.”
BackgroundParoxetine in the Treatment of Panic Disorder a Randomised, Double-Blind, Placebo-Controlled Study
Oehrberg, S., Christiansen, P. E., Behnke, K., Borup, A. L., Severin, B., Soegaard, J., Calberg, H., Judge, R., Ohrstrom, J. K., & Manniche, P. M. (1995) · British Journal of Psychiatry · doi:10.1192/bjp.167.3.374 · Cited by 261
Cited by
Prevention of Implantable-Defibrillator Shocks by Treatment with Sotalol
Pacifico, A., Hohnloser, S. H., Williams, J. H., Tao, B., Saksena, S., Henry, P. D., & Prystowsky, E. N. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402402 · Cited by 422
Redish, A. D., Jensen, S., Johnson, A., & Kurth-Nelson, Z. (2007) · Psychological Review · doi:10.1037/0033-295x.114.3.784 · Cited by 346
Psychopathology in Patients with ICDs over Time: Results of a Prospective Study
KAPA, S., ROTONDI-TREVISAN, D., MARIANO, Z., AVES, T., IRVINE, J., DORIAN, P., & HAYES, D. L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02599.x · Cited by 112
An updated review of implantable cardioverter/defibrillators, induced anxiety, and quality of life.
Bostwick, J. M., & Sola, C. L. (2007) · Psychiatric Clinics of North America · doi:10.1016/j.psc.2007.07.002 · Cited by 101
Leosdottir, M., Sigurdsson, E., Reimarsdottir, G., Gottskalksson, G., Torfason, B., Vigfusdottir, M., Eggertsson, S., & Arnar, D. O. (2006) · EP Europace · doi:10.1093/europace/euj052 · Cited by 56
Metadata
- Authors
- Bourke, J. P., Turkington, D., Thomas, G., McComb, J. M., & Tynan, M.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1997-12-01
- Volume
- 78
- Issue
- 6
- Pages
- 581-583
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2155762169
- Cited by
- 89
- References
- 2
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators. https://app.cochat.ai/papers/10.1136/hrt.78.6.581
- The paper
- Bourke, J. P., Turkington, D., Thomas, G., McComb, J. M., & Tynan, M. (1997). Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators. Heart. https://doi.org/10.1136/hrt.78.6.581
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.