Ventriculo-atrial time interval measured on M mode echocardiography: a determining element in diagnosis, treatment, and prognosis of fetal supraventricular tachycardia
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To determine whether M mode echocardiography can differentiate fetal supraventricular tachycardia according to the ventriculo-atrial (VA) time interval, and if the resulting division into short and long VA intervals holds any relation with clinical presentation, management, and fetal outcome. Design: Retrospective case series. Subjects: 23 fetuses with supraventricular tachycardia. Main outcome measures: A systematic review of the M mode echocardiograms (for VA and atrioventricular (AV) interval measurements), clinical profile, and final outcome. Results: 19 fetuses (82.6%) had supraventricular tachycardia of the short VA type (mean (SD) VA/AV ratio 0.34 (0.16); heart rate 231 (29) beats/min). Tachycardia was sustained in six and intermittent in 13. Hydrops was present in three (15.7%). Digoxin, the first drug given in 14, failed to control tachycardia in five. Three of these then received sotalol and converted to sinus rhythm. All fetuses of this group survived. Postnatally, supraventricular tachycardia recurred in three, two having Wolff-Parkinson-White syndrome. Four fetuses (17.4%) had long VA tachycardia (VA/AV ratio 3.89 (0.82); heart rate 226 (10) beats/min). Initial treatment with digoxin was ineffective in all, but sotalol was effective in two. Heart failure caused fetal death in one and premature delivery in one. All three surviving fetuses had recurrences of supraventricular tachycardia after birth: two had the permanent form of junctional reciprocating tachycardia and one had atrial ectopic tachycardia. Conclusions: Careful measurement of ventriculo-atrial intervals on fetal M mode echocardiography can be used to distinguish short from long VA supraventricular tachycardia and may be helpful in optimising management. Digoxin, when indicated, may remain the drug of choice in the short VA type but appears ineffective in the long VA type.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prenatal measurement of cardiothoracic ratio in evaluation of heart disease
Paladini, D., Chita, S. K., & Allan, L. D. (1990) · Archives of Disease in Childhood · doi:10.1136/adc.65.1_spec_no.20 · Cited by 148 · cited 1×
“Guided by bidimensional real time imaging, it was always possible to direct the M mode ultrasound beam simultaneously through the atrial and ventricular walls. VA and AV intervals, analogous to the RP and PR intervals of the extrauterine electrocardiogram, were measured at peak atrial and ventricular systolic wall mot…”
MethodEctopic automatic atrial tachycardia in children: clinical characteristics, management and follow-up
Mehta, A. V., Sanchez, G. R., Sacks, E. J., Casta, A., Dunn, J. M., & Donner, R. M. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90106-4 · Cited by 132
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Jaeggi, E. T., Carvalho, J. S., De Groot, E., Api, O., Clur, S.-A. B., Rammeloo, L., McCrindle, B. W., Ryan, G., Manlhiot, C., & Blom, N. A. (2011) · Circulation · doi:10.1161/circulationaha.111.026120 · Cited by 237
Guidelines for fetal echocardiography
Satomi, G. (2015) · Pediatrics International · doi:10.1111/ped.12467 · Cited by 44
Metadata
- Authors
- Jaeggi, E., Fouron, J. C., Fournier, A., van Doesburg, N., Drblik, S. P., & Proulx, F.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1998-06-01
- Volume
- 79
- Issue
- 6
- Pages
- 582-587
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W1966813048
- Cited by
- 95
- References
- 2
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventriculo-atrial time interval measured on M mode echocardiography: a determining element in diagnosis, treatment, and prognosis of fetal supraventricular tachycardia. https://app.cochat.ai/papers/10.1136/hrt.79.6.582
- The paper
- Jaeggi, E., Fouron, J. C., Fournier, A., van Doesburg, N., Drblik, S. P., & Proulx, F. (1998). Ventriculo-atrial time interval measured on M mode echocardiography: a determining element in diagnosis, treatment, and prognosis of fetal supraventricular tachycardia. Heart. https://doi.org/10.1136/hrt.79.6.582
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.