The DOI matches its Crossref record.
Late complications following permanent pacemaker implantation or elective unit replacement
Open accessAbstract
Objective: To determine the rate of late complications following first implantation or elective unit replacement of a permanent pacemaker system. Design: Analysis of pacemaker data and complications prospectively acquired on a computerised database. Complications were studied over an 11 year period from January 1984 to December 1994. Setting: Tertiary referral cardiothoracic centre. Patients: Records of 2621 patients were analysed retrospectively. Main outcome measures: Complications requiring repeat procedures occurring more than six weeks after pacemaker implantation or elective unit replacement. Results: The overall rate of late complications was significantly lower after first implantation of a permanent pacemaker (34 cases, complication rate 1.4%, 95% confidence interval 0.9% to 1.9%) than after elective unit replacement (16 cases, complication rate 6.5% (3.3% to 9.7%). There were 20 cases of erosion, 18 infections, five electrode problems, and seven miscellaneous problems. Complications were more common with inexperienced operators (18.9% (6.0% to 31.8%)) than with experienced operators (0.9% (0.3% to 1.5%)). Conclusions: The incidence of late complications following pacemaker implantation is low and compares favourably with early complication rates. The majority are caused by erosion and infection. Patients who have undergone elective unit replacement are at particular risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Cardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis
Zhan, C., Baine, W. B., Sedrakyan, A., & Steiner, C. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0392-0 · Cited by 266
Metadata
- Authors
- Harcombe, A. A., Newell, S. A., Ludman, P. F., Wistow, T. E., Sharples, L. D., Schofield, P. M., Stone, D. L., Shapiro, L. M., Cole, T., & Petch, M. C.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1998-09-01
- Volume
- 80
- Issue
- 3
- Pages
- 240-244
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2112419591
- Cited by
- 163
- References
- 0
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Late complications following permanent pacemaker implantation or elective unit replacement. https://app.cochat.ai/papers/10.1136/hrt.80.3.240
- The paper
- Harcombe, A. A., Newell, S. A., Ludman, P. F., Wistow, T. E., Sharples, L. D., Schofield, P. M., Stone, D. L., Shapiro, L. M., Cole, T., & Petch, M. C. (1998). Late complications following permanent pacemaker implantation or elective unit replacement. Heart. https://doi.org/10.1136/hrt.80.3.240
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.