Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 266

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Cardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis

Open access
Zhan, Chunliu, Baine, William B., Sedrakyan, Artyom, Steiner, Claudia·2008·Journal of General Internal Medicine

Abstract

OBJECTIVE: Use of cardiac devices has been increasing rapidly along with concerns over their safety and effectiveness. This study used hospital administrative data to assess cardiac device implantations in the United States, selected perioperative outcomes, and associated patient and hospital characteristics. METHODS: We screened hospital discharge abstracts from the 1997-2004 Healthcare Cost and Utilization Project Nationwide Inpatient Samples. Patients who underwent implantation of pacemaker (PM), automatic cardioverter/defibrillator (AICD), or cardiac resynchronization therapy pacemaker (CRT-P) or defibrillator (CRT-D) were identified using ICD-9-CM procedure codes. Outcomes ascertainable from these data and associated hospital and patient characteristics were analyzed. MEASUREMENTS AND MAIN RESULTS: Approximately 67,000 AICDs and 178,000 PMs were implanted in 2004 in the United States, increasing 60% and 19%, respectively, since 1997. After FDA approval in 2001, CRT-D and CRT-P reached 33,000 and 7,000 units per year in the United States in 2004. About 70% of the patients were aged 65 years or older, and more than 75% of the patients had 1 or more comorbid diseases. There were substantial decreases in length of stay, but marked increases in charges, for example, the length of stay of AICD implantations halved (from 9.9 days in 1997 to 5.2 days in 2004), whereas charges nearly doubled (from $66,000 in 1997 to $117,000 in 2004). Rates of in-hospital mortality and complications fluctuated slightly during the period. Overall, adverse outcomes were associated with advanced age, comorbid conditions, and emergency admissions, and there was no consistent volume-outcome relationship across different outcome measures and patient groups. CONCLUSIONS: The numbers of cardiac device implantations in the United States steadily increased from 1997 to 2004, with substantial reductions in length of stay and increases in charges. Rates of in-hospital mortality and complications changed slightly over the years and were associated primarily with patient frailty.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11606-007-0392-0

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 266

Metadata

Authors
Zhan, C., Baine, W. B., Sedrakyan, A., & Steiner, C.
Venue
Journal of General Internal Medicine
Published
2007-12-19
Volume
23
Issue
S1
Pages
13-19
ISSN
  • 0884-8734 (ISSN-L)
  • 1525-1497
OpenAlex
W1999349447
Cited by
266
References
39
FWCI
6.70
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis. https://app.cochat.ai/papers/10.1007/s11606-007-0392-0
The paper
Zhan, C., Baine, W. B., Sedrakyan, A., & Steiner, C. (2008). Cardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis. Journal of General Internal Medicine. https://doi.org/10.1007/s11606-007-0392-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.