Open accessAbstract
OBJECTIVE: To review the safety and efficacy of the Amplatzer septal occluder for transcatheter closure of interatrial communications (atrial septal defects (ASD), fenestrated Fontan (FF), patent foramen ovale (PFO)). DESIGN: Prospective study following a common protocol for patient selection and technique of deployment in all participating centres. SETTING: Multicentre study representing total United Kingdom experience. PATIENTS: First 100 consecutive patients in whom an Amplatzer septal occluder was used to close a clinically significant ASD or interatrial communication. INTERVENTIONS: All procedures performed under general anaesthesia with transoesophageal echocardiographic guidance. Interatrial communications were assessed by transoesophageal echocardiography with reference to size, position in the interatrial septum, proximity to surrounding structures, and adequacy of septal rim. Stretched diameter of the interatrial communications was determined by balloon sizing. Device selection was based on and matched to the stretched diameter of the communication. MAIN OUTCOME MEASURES: Success defined as deployment of device in a stable position to occlude the interatrial communication without inducing functional abnormality or anatomical obstruction. Occlusion status determined by transoesophageal echocardiography during procedure and by transthoracic echocardiography on follow up. Clinical status and occlusion rates assessed at 24 hours, one month, and three months. RESULTS: 101 procedures were performed in 100 patients (86 ASD, 7 FF, 7 PFO), age 1.7 to 64.3 years (mean (SD), 13.3 (13.9)), weight 9.2 to 100.0 kg (mean 32.5 (23.5)). Procedure time ranged from 30 to 180 minutes (mean 92.4 (29.0)) and fluoroscopy time from 6.0 to 49.0 minutes (mean 16.1 (8.0)). There were seven failures, all occurring in patients with ASD, and one embolisation requiring surgical removal. Immediate total occlusion rate was 20.4%, rising to 84.9% after 24 hours. Total occlusion rates at the one and three month follow up were 92.5% and 98.9%, respectively. Complications were: transient ST elevation (1), transient atrioventricular block (1), presumed deep vein thrombosis (1), presumed transient ischaemic attack (1). CONCLUSIONS: It appears feasible to close interatrial communications and atrial septal defects up to 26 mm stretched diameter safely with the Amplatzer septal occluder. Short term results confirm an early high occlusion rate with no major complications. Careful selection of cases based on the echocardiographic morphology of the ASD and accurate assessment of their stretched diameter is of utmost importance. Further experience with the larger devices and longer term results are required before a firm conclusion regarding its use can be made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of surgical and medical therapy for atrial septal defect in adults
Konstantinides, S., Geibel, A., Olschewski, M., Görnandt, L., Roskamm, H., Spillner, G., Just, H., & Kasper, W. (1995) · New England Journal of Medicine · doi:10.1056/nejm199508243330801 · Cited by 406
Cited by
Chessa, M., Carminati, M., Butera, G., Bini, R. M., Drago, M., Rosti, L., Giamberti, A., Pomè, G., Bossone, E., & Frigiola, A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01711-4 · Cited by 593
Biomedical Applications of Shape Memory Alloys
Petrini, L., & Migliavacca, F. (2011) · Journal of Metallurgy · doi:10.1155/2011/501483 · Cited by 585
Antithrombotic and Thrombolytic Therapy for Ischemic Stroke
Albers, G. W., Amarenco, P., Easton, J. D., Sacco, R. L., & Teal, P. (2004) · Chest · doi:10.1378/chest.126.3_suppl.483s · Cited by 466
Antithrombotic and Thrombolytic Therapy for Ischemic Stroke
Albers, G. W., Amarenco, P., Easton, J. D., Sacco, R. L., & Teal, P. (2008) · Chest · doi:10.1378/chest.08-0720 · Cited by 320
Fischer, G., Stieh, J., Uebing, A., Hoffmann, U., Morf, G., & Kramer, H. H. (2003) · Heart · doi:10.1136/heart.89.2.199 · Cited by 288
Metadata
- Authors
- Chan, K. C., Godman, M. J., Walsh, K., Wilson, N., Redington, A., & Gibbs, J. L.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1999-09-01
- Volume
- 82
- Issue
- 3
- Pages
- 300-306
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2124679490
- Cited by
- 307
- References
- 1
- FWCI
- 18.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience. https://app.cochat.ai/papers/10.1136/hrt.82.3.300
- The paper
- Chan, K. C., Godman, M. J., Walsh, K., Wilson, N., Redington, A., & Gibbs, J. L. (1999). Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience. Heart. https://doi.org/10.1136/hrt.82.3.300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.