CoChat

The Accuracy of Medication Data in an Outpatient Electronic Medical Record

Open access
Wagner, M. M., Hogan, W. R. · 1996 · Journal of the American Medical Informatics Association
Cited by 123

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To measure the accuracy of medication records stored in the electronic medical record (EMR) of an outpatient geriatric center. The authors analyzed accuracy from the perspective of a clinician using the data and the perspective of a computer-based medical decision-support system (MDSS). DESIGN: Prospective cohort study. METHODS: The EMR at the geriatric center captures medication data both directly from clinicians and indirectly using encounter forms and data-entry clerks. During a scheduled office visit for medical care, the treating clinician determined whether the medication records for the patient were an accurate representation of the medications that the patient was actually taking. Using the available sources of information (the patient, the patient's vials, any caregivers, and the medical chart), the clinician determined whether the recorded data were correct, whether any data were missing, and the type and cause for each discrepancy found. RESULTS: At the geriatric center, 83% of medication records represented correctly the compound. dose, and schedule of a current medication; 91% represented correctly the compound. 0.37 current medications were missing per patient. The principal cause of errors was the patient (36.1% of errors), who misreported a medication at a previous visit or changed (stopped, started, or dose-adjusted) a medication between visits. The second most frequent cause of errors was failure to capture changes to medications made by outside clinicians, accounting for 25.9% of errors. Transcription errors were a relatively ucommon cause (8.2% of errors). When the accuracy of records from the center was analyzed from the perspective of a MDSS, 90% were correct for compound identity and 1.38 medications were missing or uncoded per patient. The cause of the additional errors of omission was a free-text "comments" field-which it is assumed would be unreadable by current MDSS applications-that was used by clinicians in 18% of records to record the identity of the medication. CONCLUSIONS: Medication records in an outpatient EMR may have significant levels of data error. Based on an analysis of correctable causes of error, the authors conclude that the most effective extension to the EMR studied would be to expand its scope to include all clinicians who can potentially change medications. Even with EMR extensions, however, ineradicable error due to patients and data entry will remain. Several implications of ineradicable error for MDSSs are discussed. The provision of a free-text "comments" field increased the accuracy of medication lists for clinician users at the expense of accuracy for a MDSS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jamia.1996.96310637

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 123

Metadata

Authors
Wagner, M. M., & Hogan, W. R.
Venue
Journal of the American Medical Informatics Association
Published
1996-05-01
Volume
3
Issue
3
Pages
234-244
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2114981196
Cited by
123
References
3
FWCI
3.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Accuracy of Medication Data in an Outpatient Electronic Medical Record. https://app.cochat.ai/papers/10.1136/jamia.1996.96310637
The paper
Wagner, M. M., & Hogan, W. R. (1996). The Accuracy of Medication Data in an Outpatient Electronic Medical Record. Journal of the American Medical Informatics Association. https://doi.org/10.1136/jamia.1996.96310637

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.