CoChat

Enabling digital pathology in the diagnostic setting: navigating through the implementation journey in an academic medical centre

Cheng, Chee Leong, Azhar, Rafay, Sng, Shi Hui Adeline, Chua, Yong Quan, Hwang, Jacqueline Siok Gek, Chin, Jennifer Poi Fun, Seah, Waih Khuen, Loke, Janel Chui Ling, Ang, Roy Hang Leng, Tan, Puay Hoon · 2016 · Journal of Clinical Pathology
Cited by 76

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Aims: As digital pathology (DP) and whole slide imaging (WSI) technology advance and mature, there is an increasing drive to incorporate DP into the diagnostic environment. However, integration of DP into the diagnostic laboratory is a non-trivial task and filled with unexpected challenges unlike standalone implementations. We share our journey of implementing DP in the diagnostic laboratory setting, highlighting seven key guiding principles that drive the progression through implementation into deployment and beyond. Methods: The DP implementation with laboratory information system integration was completed in 8 months, including validation of the solution for diagnostic use in accordance with College of American Pathologists guidelines. We also conducted prospective validation via paired delivery of glass slides and WSI to our pathologists postdeployment. Results: Common themes in our guiding principles included emphasis on workflow and being comprehensive in the approach, looking beyond pathologist user champions and expanding into an extended project team involving laboratory technicians, clerical/data room staff and archival staff. Concordance between glass slides and WSI ranged from 93% to 100% among various applications on validation. We also provided equal opportunities for every pathologist throughout the department to be competent and confident with DP through prospective validation, with overall concordance of 96% compared with glass slides, allowing appreciation of the advantages and limitations of WSI, hence enabling the use of DP as a useful diagnostic modality. Conclusions: Smooth integration of DP into the diagnostic laboratory is possible with careful planning, discipline and a systematic approach adhering to our guiding principles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jclinpath-2015-203600

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 76

Metadata

Authors
Cheng, C. L., Azhar, R., Sng, S. H. A., Chua, Y. Q., Hwang, J. S. G., Chin, J. P. F., Seah, W. K., Loke, J. C. L., Ang, R. H. L., & Tan, P. H.
Venue
Journal of Clinical Pathology
Publisher
BMJ
Published
2016-02-12
Volume
69
Issue
9
Pages
784-792
ISSN
  • 0021-9746 (ISSN-L)
  • 1472-4146
OpenAlex
W2338965302
Cited by
76
References
1
FWCI
6.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.