CoChat

Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study)

Open access

The DOI matches its Crossref record; 54 of the 56 references it cites were found in a registry or an index.

Abstract

Most prior studies of primary diagnosis in surgical pathology using whole slide imaging (WSI) versus microscopy have focused on specific organ systems or included relatively few cases. The objective of this study was to demonstrate that WSI is noninferior to microscopy for primary diagnosis in surgical pathology. A blinded randomized noninferiority study was conducted across the entire range of surgical pathology cases (biopsies and resections, including hematoxylin and eosin, immunohistochemistry, and special stains) from 4 institutions using the original sign-out diagnosis (baseline diagnosis) as the reference standard. Cases were scanned, converted to WSI and randomized. Sixteen pathologists interpreted cases by microscopy or WSI, followed by a wash-out period of ≥4 weeks, after which cases were read by the same observers using the other modality. Major discordances were identified by an adjudication panel, and the differences between major discordance rates for both microscopy (against the reference standard) and WSI (against the reference standard) were calculated. A total of 1992 cases were included, resulting in 15,925 reads. The major discordance rate with the reference standard diagnosis was 4.9% for WSI and 4.6% for microscopy. The difference between major discordance rates for microscopy and WSI was 0.4% (95% confidence interval, -0.30% to 1.01%). The difference in major discordance rates for WSI and microscopy was highest in endocrine pathology (1.8%), neoplastic kidney pathology (1.5%), urinary bladder pathology (1.3%), and gynecologic pathology (1.2%). Detailed analysis of these cases revealed no instances where interpretation by WSI was consistently inaccurate compared with microscopy for multiple observers. We conclude that WSI is noninferior to microscopy for primary diagnosis in surgical pathology, including biopsies and resections stained with hematoxylin and eosin, immunohistochemistry and special stains. This conclusion is valid across a wide variety of organ systems and specimen types.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pas.0000000000000948

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Figures

FIGURE 1 Study design.
FIGURE 1 Study design.CC BY-NC-ND · PubMed Central
FIGURE 2 Difference in major discordance rates between WSI (WSI vs. reference standard) and microscopy (microscopy vs. reference standard) for each of 20 organ systems included in the study. The y-axis is the difference (in %) between the major discordance rate for WSI and the major discordance rate for microscopy. The x-axis lists the organ systems. For any given organ system, a WSI minus microscopy difference >0 indicates that the overall major discordance rate for that organ system was greater for WSI than for microscopy. A negative percentage indicates that the major discordance rate for that organ system was greater for microscopy than for WSI. BD indicates bile duct; GE, gastroesophageal.
FIGURE 2 Difference in major discordance rates between WSI (WSI vs. reference standard) and microscopy (microscopy vs. reference standard) for each of 20 organ systems included in the study. The y-axis is the difference (in %) between the major discordance rate for WSI and the major discordance rate for microscopy. The x-axis lists the organ systems. For any given organ system, a WSI minus microscopy difference >0 indicates that the overall major discordance rate for that organ system was greater for WSI than for microscopy. A negative percentage indicates that the major discordance rate for that organ system was greater for microscopy than for WSI. BD indicates bile duct; GE, gastroesophageal.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 399

Metadata

Authors
Mukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., Gill, R. M., Heaton, R. P., Kerstens, R., Lindberg, G. M., Malhotra, R. K., Mandell, J. W., Manlucu, E. D., Mills, A. M., Mills, S. E., Moskaluk, C. A., Nelis, M., Patil, D. T., Przybycin, C. G., Reynolds, J. P., Rubin, B. P., Saboorian, M. H., Salicru, M., Samols, M. A., Sturgis, C. D., Turner, K. O., Wick, M. R., Yoon, J. Y., Zhao, P., & Taylor, C. R.
Affiliations
  • Cleveland Clinic (US)
  • Hospital of the University of Pennsylvania (US)
  • Philips (Netherlands) (NL)
  • Miraca Life Sciences, Irving, TX
  • Advanced Pathology Associates, Silver Spring, MD
  • University of Virginia (US)
  • Department of Pathology, Indiana University School of Medicine, Indianapolis, IA
  • University of California, San Francisco (US)
  • University of Southern California (US)
Corresponding author
  • Mukhopadhyay, Sanjay
  • Gill, Ryan M.
  • Patil, Deepa T.
  • Przybycin, Christopher G.
  • Reynolds, Jordan P.
  • Rubin, Brian P.
  • Sturgis, Charles D.
Venue
American Journal of Surgical Pathology
Published
2018-01
Volume
42
Issue
1
Pages
39-52
ISSN
0147-5185 (ISSN-L)
OpenAlex
W2759004613
Cited by
399
References
56
Citations by year
2026: 31 · 2025: 30 · 2024: 44 · 2023: 50 · 2022: 55 · 2021: 71 · 2020: 64 · 2019: 32 · 2018: 22
FWCI
19.24
Type
journal article
Language
en
Open access
Locations
  • The American Journal of Surgical Pathology (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • IUScholarWorks (Indiana University) (submittedVersion, cc-by-nc-nd)
  • Purdue University Indianapolis (Indiana University) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
whole slide imaging, microscopy, primary diagnosis, surgical pathology, diagnostic discordance, non-inferiority, H&E staining, immunohistochemistry, special stains, endocrine pathology, kidney pathology, urinary bladder pathology, gynecologic pathology
MeSH terms
Humans, Microscopy, Pathology, Surgical, Reproducibility of Results, Observer Variation, Single-Blind Method, Histocytological Preparation Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study). https://app.cochat.ai/papers/10.1097/pas.0000000000000948
The paper
Mukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., Gill, R. M., Heaton, R. P., Kerstens, R., Lindberg, G. M., Malhotra, R. K., Mandell, J. W., Manlucu, E. D., Mills, A. M., Mills, S. E., . . . Taylor, C. R. (2018). Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study). American Journal of Surgical Pathology. https://doi.org/10.1097/pas.0000000000000948

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.