Diagnostic concordance and discordance in digital pathology: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: Digital pathology (DP) has the potential to fundamentally change the way that histopathology is practised, by streamlining the workflow, increasing efficiency, improving diagnostic accuracy and facilitating the platform for implementation of artificial intelligence–based computer-assisted diagnostics. Although the barriers to wider adoption of DP have been multifactorial, limited evidence of reliability has been a significant contributor. A meta-analysis to demonstrate the combined accuracy and reliability of DP is still lacking in the literature. Objectives: We aimed to review the published literature on the diagnostic use of DP and to synthesise a statistically pooled evidence on safety and reliability of DP for routine diagnosis (primary and secondary) in the context of validation process. Methods: A comprehensive literature search was conducted through PubMed, Medline, EMBASE, Cochrane Library and Google Scholar for studies published between 2013 and August 2019. The search protocol identified all studies comparing DP with light microscopy (LM) reporting for diagnostic purposes, predominantly including H&E-stained slides. Random-effects meta-analysis was used to pool evidence from the studies. Results: Twenty-five studies were deemed eligible to be included in the review which examined a total of 10 410 histology samples (average sample size 176). For overall concordance (clinical concordance), the agreement percentage was 98.3% (95% CI 97.4 to 98.9) across 24 studies. A total of 546 major discordances were reported across 25 studies. Over half (57%) of these were related to assessment of nuclear atypia, grading of dysplasia and malignancy. These were followed by challenging diagnoses (26%) and identification of small objects (16%). Conclusion: The results of this meta-analysis indicate equivalent performance of DP in comparison with LM for routine diagnosis. Furthermore, the results provide valuable information concerning the areas of diagnostic discrepancy which may warrant particular attention in the transition to DP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayyan-a web and mobile app for systematic reviews.
Ouzzani, M., Hammady, H., Fedorowicz, Z., & Elmagarmid, A. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0384-4 · Cited by 26,092
Artificial intelligence in digital pathology — new tools for diagnosis and precision oncology
Bera, K., Schalper, K. A., Rimm, D. L., Velcheti, V., & Madabhushi, A. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0252-y · Cited by 1,698
Mukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., et al. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000948 · Cited by 399
Pantanowitz, L., Sharma, A., Carter, A. B., Kurc, T., Sussman, A., & Saltz, J. (2018) · Journal of Pathology Informatics · doi:10.4103/jpi.jpi_69_18 · Cited by 282
Validation of digital pathology imaging for primary histopathological diagnosis
Snead, D. R. J., Tsang, Y., Meskiri, A., Kimani, P. K., Crossman, R., Rajpoot, N. M., Blessing, E., Chen, K., Gopalakrishnan, K., Matthews, P., et al. (2016) · Histopathology · doi:10.1111/his.12879 · Cited by 238
Self-citationmeta: General Package for Meta-Analysis
Schwarzer, G. (2006) · CRAN: Contributed Packages · doi:10.32614/cran.package.meta · Cited by 202
Evans, A. J., Bauer, T. W., Bui, M. M., Cornish, T. C., Duncan, H., Glassy, E. F., Hipp, J., McGee, R. S., Murphy, D., Myers, C., et al. (2018) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2017-0496-cp · Cited by 168
Cited by
Digital Pathology: Advantages, Limitations and Emerging Perspectives
Jahn, S. W., Plass, M., & Moinfar, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113697 · Cited by 348
Fast and scalable search of whole-slide images via self-supervised deep learning
Chen, C., Lu, M. Y., Williamson, D. F. K., Chen, T. Y., Schaumberg, A. J., & Mahmood, F. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00929-8 · Cited by 130
Naoumov, N. V., Brees, D., Loeffler, J., Chng, E., Ren, Y., Lopez, P., Tai, D., Lamle, S., & Sanyal, A. J. (2022) · Journal of Hepatology · doi:10.1016/j.jhep.2022.06.018 · Cited by 115
Jayakumar, S., Sounderajah, V., Normahani, P., Harling, L., Markar, S. R., Ashrafian, H., & Darzi, A. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00544-y · Cited by 110
“Only one review provided a tabular display of QUADAS assessment in the recommended format 17 and reported low risk of bias among the majority of included studies across all domains (Patient Selection: 64% of studies low risk; Index Test: 80% low risk; Reference Standard: 92% low risk; Flow and…”
Background
Metadata
- Authors
- Azam, A. S., Miligy, I. M., Kimani, P. K.-U., Maqbool, H., Hewitt, K., Rajpoot, N. M., & Snead, D. R. J.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 2020-09-15
- Volume
- 74
- Issue
- 7
- Pages
- 448-455
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W3084983573
- Cited by
- 83
- References
- 7
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic concordance and discordance in digital pathology: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1136/jclinpath-2020-206764
- The paper
- Azam, A. S., Miligy, I. M., Kimani, P. K.-U., Maqbool, H., Hewitt, K., Rajpoot, N. M., & Snead, D. R. J. (2021). Diagnostic concordance and discordance in digital pathology: a systematic review and meta-analysis. Journal of Clinical Pathology. https://doi.org/10.1136/jclinpath-2020-206764
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.