Cited by 35AI in cancer detectionArtificial Intelligence in Healthcare and EducationColorectal Cancer Screening and Detection

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Accuracy of GPT-4 in histopathological image detection and classification of colorectal adenomas

Abstract

AIMS: To evaluate the accuracy of Chat Generative Pre-trained Transformer (ChatGPT) powered by GPT-4 in histopathological image detection and classification of colorectal adenomas using the diagnostic consensus provided by pathologists as a reference standard. METHODS: A study was conducted with 100 colorectal polyp photomicrographs, comprising an equal number of adenomas and non-adenomas, classified by two pathologists. These images were analysed by classic GPT-4 for 1 time in October 2023 and custom GPT-4 for 20 times in December 2023. GPT-4's responses were compared against the reference standard through statistical measures to evaluate its proficiency in histopathological diagnosis, with the pathologists further assessing the model's descriptive accuracy. RESULTS: GPT-4 demonstrated a median sensitivity of 74% and specificity of 36% for adenoma detection. The median accuracy of polyp classification varied, ranging from 16% for non-specific changes to 36% for tubular adenomas. Its diagnostic consistency, indicated by low kappa values ranging from 0.06 to 0.11, suggested only poor to slight agreement. All of the microscopic descriptions corresponded with their diagnoses. GPT-4 also commented about the limitations in its diagnoses (eg, slide diagnosis best done by pathologists, the inadequacy of single-image diagnostic conclusions, the need for clinical data and a higher magnification view). CONCLUSIONS: GPT-4 showed high sensitivity but low specificity in detecting adenomas and varied accuracy for polyp classification. However, its diagnostic consistency was low. This artificial intelligence tool acknowledged its diagnostic limitations, emphasising the need for a pathologist's expertise and additional clinical context.

Overview

Integrity signals

Registry

Crossref · 10.1136/jcp-2023-209304

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Research works printed but not linked: 1

  1. OpenAI . GPT-4 technical report. 2023. Available: https://arxiv.org/pdf/2303.08774.pdf · arXiv

Cited by

Sorted by citations

See all 35

Metadata

Authors
Laohawetwanit, T., Namboonlue, C., & Apornvirat, S.
Affiliations
  • Thammasat University (TH)
  • Dr Pong Clinic, Bangkok, Thailand
Corresponding author
Laohawetwanit, Thiyaphat
Venue
Journal of Clinical Pathology
Publisher
BMJ
Published
2024-01-10
Volume
78
Issue
3
Pages
202-207
ISSN
  • 0021-9746 (ISSN-L)
  • 1472-4146
OpenAlex
W4390708138
Cited by
35
References
20
Citations by year
2026: 4 · 2025: 14 · 2024: 17
FWCI
5.17
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Pathology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Oncology › Colorectal Cancer Screening and Detection
Keywords
GPT-4, large language models, colorectal adenoma, colorectal polyps, histopathological image classification, adenoma detection, polyp classification, diagnostic accuracy, diagnostic consistency, artificial intelligence in pathology
MeSH terms
Adenoma, Colonic Polyps, Humans, Image Interpretation, Computer-Assisted, Sensitivity and Specificity, Colorectal Neoplasms, Reproducibility of Results, Observer Variation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of GPT-4 in histopathological image detection and classification of colorectal adenomas. https://app.cochat.ai/papers/10.1136/jcp-2023-209304
The paper
Laohawetwanit, T., Namboonlue, C., & Apornvirat, S. (2025). Accuracy of GPT-4 in histopathological image detection and classification of colorectal adenomas. Journal of Clinical Pathology. https://doi.org/10.1136/jcp-2023-209304