Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record.

Estimation of hydroxyproline by the AutoAnalyser

Open access
Grant, R. A.·1964·Journal of Clinical Pathology

Abstract

A method has been developed for the determination of hydroxyproline by the Technicon AutoAnalyserl using a modified version of the Stegemann assay (1958).This involves oxidation of the hydroxyproline with chlor- amine T; excess chloramine T is destroyed with per- chloric acid and the hydroxyproline chromogen is then reacted with p-dimethylaminobenzaldehyde to develop a pink colour.In the present method the absorption is measured at 550 my.The reagents used are adapted from the method described by Woessner (1961), in particular the composition of the p-dimethylaminobenzaldehyde solution (P.D.A. reagent) has been changed to avoid precipitation in the transmission tubing.This method has been applied to the determination of collagen and elastin in arteries and connective tissues and the results obtained agree well with those found using a manual method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jcp.17.6.685

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Grant, R. A.
Venue
Journal of Clinical Pathology
Publisher
BMJ
Published
1964-11
Volume
17
Issue
6
Pages
685-686
ISSN
  • 0021-9746 (ISSN-L)
  • 1472-4146
OpenAlex
W4322701725
Cited by
200
References
0
FWCI
3.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of hydroxyproline by the AutoAnalyser. https://app.cochat.ai/papers/10.1136/jcp.17.6.685
The paper
Grant, R. A. (1964). Estimation of hydroxyproline by the AutoAnalyser. Journal of Clinical Pathology. https://doi.org/10.1136/jcp.17.6.685

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.