Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Diabetes mellitus is an important diagnosis. New criteria have been defined for impaired glucose metabolism and, accordingly, there is a need for precise and accurate glucose analysis for the correct classification of patients. However, neither the World Health Organisation nor the National Service Framework for Diabetes in England and Wales deal with the associated analytical issues for plasma glucose. Aims/Methods: To compare two different methods for plasma glucose with respect to European and CLIA ’88 quality requirements. Results: Using several different graphical and statistical techniques, the YSI 2300 STAT was found to be 8.1–8.4% negatively biased for plasma glucose when compared with the Olympus AU640 method. Conclusions: Such a large bias would have a large impact on the detection of diabetes mellitus in clinical practice and therefore this method should not be used to make a definitive diagnosis. The bias probably results from the fact that the YSI 2300 STAT uses an aqueous based standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79
Research works printed but not linked: 8
- 10.2337/diacare.20.7.1183 · DOI · Paper page
- 2002, Clin Chem, 48, 436, 10.1093/clinchem/48.3.436 · DOI · Paper page
- 1997, Ann Clin Biochem, 34, 8, 10.1177/000456329703400103 · DOI · Paper page
- 1992, Federal Register, 57, 7002
- 1999, Clin Chem, 45, 882, 10.1093/clinchem/45.6.882 · DOI
- 1995, Clin Lab Sci, 8, 277
- 1997, Eur J Clin Chem Clin Biochem, 35, 845
- 1978, Clin Chem, 24, 150, 10.1093/clinchem/24.1.150 · DOI
Cited by
Global Prevalence of Diabetes: Estimates for the Year 2000 and Projections for 2030
Wild, S. H., Roglic, G., Green, A., Sicree, R., & King, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.10.2569-a · Cited by 1,477
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
Measures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202
System Accuracy Evaluation of 27 Blood Glucose Monitoring Systems According to DIN EN ISO 15197
Freckmann, G., Baumstark, A., Jendrike, N., Zschornack, E., Kocher, S., Tshiananga, J., Heister, F., & Haug, C. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0128 · Cited by 195
“For example, Twomey 18 found the YSI 2300 STAT, using the glucose oxidase method, to be negatively biased for plasma glucose when compared with the Olympus (Tokyo, Japan) AU640 (cid”
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Metadata
- Authors
- Twomey, P. J.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 2004-06-25
- Volume
- 57
- Issue
- 7
- Pages
- 752-754
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W2007812232
- Cited by
- 74
- References
- 3
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640. https://app.cochat.ai/papers/10.1136/jcp.2003.013417
- The paper
- Twomey, P. J. (2004). Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640. Journal of Clinical Pathology. https://doi.org/10.1136/jcp.2003.013417
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.