The DOI matches its Crossref record.
Imaging of vertebral artery stenosis: a systematic review
Open accessAbstract
BACKGROUND AND PURPOSE: Posterior circulation stroke accounts for 20% of ischaemic strokes. Recent data suggest that the early stroke recurrence risk is high and comparable with carotid artery disease. Vertebral artery stenosis accounts for approximately 20% of posterior circulation stroke, and with endovascular treatment available accurate diagnostic imaging is important. We performed a systematic literature review to validate the accuracy of the non-invasive imaging techniques Duplex ultrasound (DUS), magnetic resonance angiography (MRA) and computed tomographic angiography (CTA) in detecting severe vertebral artery stenosis, with intra-arterial angiography (IAA) as the reference standard. METHODS: We identified studies that used non-invasive imaging and IAA as the reference standard to determine vertebral artery stenosis and provided adequate data to calculate sensitivity and specificity. We analysed the quality of these studies, looked for evidence of heterogeneity and performed subgroup analysis for different degrees of stenosis. RESULTS: 11 studies categorised stenosis into 50-99%. The sensitivity of CTA (single study) and pooled sensitivities of contrast enhanced MRA (CE-MRA) and colour duplex were 100% (95% CI 15.8 to 100), 93.9% (79.8 to 99.3) and 70.2% (54.2 to 83.3), respectively. The specificities for CTA, CE-MRA and colour duplex were 95.2% (83.8 to 99.4), 94.8% (91.1 to 97.3) and 97.7% (95.2 to 99.1). However, specificities for CE-MRA and colour duplex demonstrated significant heterogeneity (p = 0.003 and p = 0.002, respectively). CONCLUSIONS: CE-MRA and possibly CTA may be more sensitive in diagnosing vertebral artery stenosis than DUS. However, data are limited and further high quality studies comparing DUS, MRA and CTA with IAA are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx095 · Cited by 3,293
Guidelines for Management of Ischaemic Stroke and Transient Ischaemic Attack 2008
(2008) · Cerebrovascular Diseases · doi:10.1159/000131083 · Cited by 2,489
ESC Guidelines on the diagnosis and treatment of peripheral artery diseases
Endorsed by: the European Stroke Organisation (ESO), Authors/Task Force Members, Tendera, M., Aboyans, V., Bartelink, M.-L., Baumgartner, I., Clément, D., Collet, J.-P., Cremonesi, A., De Carlo, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr211 · Cited by 1,506
Naylor, A. R., Ricco, J.-B., de Borst, G. J., Debus, S., de Haro, J., Halliday, A., Hamilton, G., Kakisis, J., Kakkos, S., Lepidi, S., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2017.06.021 · Cited by 1,165
Self-citationAboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2017.07.018 · Cited by 963
Metadata
- Authors
- Khan, S., Cloud, G. C., Kerry, S., & Markus, H. S.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 2007-11-01
- Volume
- 78
- Issue
- 11
- Pages
- 1218-1225
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2123959588
- Cited by
- 172
- References
- 0
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging of vertebral artery stenosis: a systematic review. https://app.cochat.ai/papers/10.1136/jnnp.2006.111716
- The paper
- Khan, S., Cloud, G. C., Kerry, S., & Markus, H. S. (2007). Imaging of vertebral artery stenosis: a systematic review. Journal of Neurology, Neurosurgery & Psychiatry. https://doi.org/10.1136/jnnp.2006.111716
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.