CoChat

Brain penetration effects of microelectrodes and DBS leads in STN or GPi

Open access
Mann, J M, Foote, K D, Garvan, C W, Fernandez, H H, Jacobson, C E, Rodriguez, R L, Haq, I U, Siddiqui, M S, Malaty, I A, Morishita, T, Hass, C J, Okun, M S · 2009 · Journal of Neurology, Neurosurgery & Psychiatry
Cited by 146

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To determine how intraoperative microelectrode recordings (MER) and intraoperative lead placement acutely influence tremor, rigidity, and bradykinesia. Secondarily, to evaluate whether the longevity of the MER and lead placement effects were influenced by target location (subthalamic nucleus (STN) or globus pallidus interna (GPi)). BACKGROUND: Currently most groups who perform deep brain stimulation (DBS) for Parkinson disease (PD) use MER, as well as macrostimulation (test stimulation), to refine DBS lead position. Following MER and/or test stimulation, however, there may be a resultant "collision/implantation" or "microlesion" effect, thought to result from disruption of cells and/or fibres within the penetrated region. These effects have not been carefully quantified. METHODS: 47 consecutive patients with PD undergoing unilateral DBS for PD (STN or GPi DBS) were evaluated. Motor function was measured at six time points with a modified motor Unified Parkinson Disease Rating Scale (UPDRS): (1) preoperatively, (2) immediately after MER, (3) immediately after lead implantation/collision, (4) 4 months following surgery-off medications, on DBS (12 h medication washout), (5) 6 months postoperatively-off medication and off DBS (12 h washout) and (6) 6 months-on medication and off DBS (12 h washout). RESULTS: Significant improvements in motor scores (p<0.05) (tremor, rigidity, bradykinesia) were observed as a result of MER and lead placement. The improvements were similar in magnitude to what was observed at 4 and 6 months post-DBS following programming and medication optimisation. When washed out (medications and DBS) for 12 h, UPDRS motor scores were still improved compared with preoperative testing. There was a larger improvement in STN compared with GPi following MER (p<0.05) and a trend for significance following lead placement (p<0.08) but long term outcome was similar. CONCLUSION: This study demonstrated significant acute intraoperative penetration effects resulting from MER and lead placement/collision in PD. Clinicians rating patients in the operating suite should be aware of these effects, and should consider pre- and post-lead placement rating scales prior to activating DBS. The collision/implantation effects were greater intraoperatively with STN compared with GPi, and with greater disease duration there was a larger effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jnnp.2008.159558

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mann, J. M., Foote, K. D., Garvan, C. W., Fernandez, H. H., Jacobson, C. E., Rodriguez, R. L., Haq, I. U., Siddiqui, M. S., Malaty, I. A., Morishita, T., Hass, C. J., & Okun, M. S.
Venue
Journal of Neurology, Neurosurgery & Psychiatry
Publisher
BMJ
Published
2009-02-22
Volume
80
Issue
7
Pages
794-798
ISSN
0022-3050 (ISSN-L)
OpenAlex
W1969088624
Cited by
146
References
0
FWCI
6.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.