Brain penetration effects of microelectrodes and DBS leads in STN or GPi
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine how intraoperative microelectrode recordings (MER) and intraoperative lead placement acutely influence tremor, rigidity, and bradykinesia. Secondarily, to evaluate whether the longevity of the MER and lead placement effects were influenced by target location (subthalamic nucleus (STN) or globus pallidus interna (GPi)). BACKGROUND: Currently most groups who perform deep brain stimulation (DBS) for Parkinson disease (PD) use MER, as well as macrostimulation (test stimulation), to refine DBS lead position. Following MER and/or test stimulation, however, there may be a resultant "collision/implantation" or "microlesion" effect, thought to result from disruption of cells and/or fibres within the penetrated region. These effects have not been carefully quantified. METHODS: 47 consecutive patients with PD undergoing unilateral DBS for PD (STN or GPi DBS) were evaluated. Motor function was measured at six time points with a modified motor Unified Parkinson Disease Rating Scale (UPDRS): (1) preoperatively, (2) immediately after MER, (3) immediately after lead implantation/collision, (4) 4 months following surgery-off medications, on DBS (12 h medication washout), (5) 6 months postoperatively-off medication and off DBS (12 h washout) and (6) 6 months-on medication and off DBS (12 h washout). RESULTS: Significant improvements in motor scores (p<0.05) (tremor, rigidity, bradykinesia) were observed as a result of MER and lead placement. The improvements were similar in magnitude to what was observed at 4 and 6 months post-DBS following programming and medication optimisation. When washed out (medications and DBS) for 12 h, UPDRS motor scores were still improved compared with preoperative testing. There was a larger improvement in STN compared with GPi following MER (p<0.05) and a trend for significance following lead placement (p<0.08) but long term outcome was similar. CONCLUSION: This study demonstrated significant acute intraoperative penetration effects resulting from MER and lead placement/collision in PD. Clinicians rating patients in the operating suite should be aware of these effects, and should consider pre- and post-lead placement rating scales prior to activating DBS. The collision/implantation effects were greater intraoperatively with STN compared with GPi, and with greater disease duration there was a larger effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Therapeutic deep brain stimulation reduces cortical phase-amplitude coupling in Parkinson's disease
de Hemptinne, C., Swann, N. C., Ostrem, J. L., Ryapolova-Webb, E. S., San Luciano, M., Galifianakis, N. B., & Starr, P. A. (2015) · Nature Neuroscience · doi:10.1038/nn.3997 · Cited by 623
“All data were recorded 5 to 60 minutes after lead insertion in order to minimize the confounding effect of temporary ‘microlesion’ associated caused by lead insertion 54, 55 .”
Subcallosal Cingulate Deep Brain Stimulation for Treatment-Resistant Unipolar and Bipolar Depression
Holtzheimer, P. E. (2012) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2011.1456 · Cited by 608
Okun, M. S., Gallo, B. V., Mandybur, G., Jagid, J., Foote, K. D., Revilla, F. J., Alterman, R., Jankovic, J., Simpson, R., Junn, F., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70308-8 · Cited by 409
Self-citationGilron, R., Little, S., Perrone, R., Wilt, R., de Hemptinne, C., Yaroshinsky, M. S., Racine, C. A., Wang, S. S., Ostrem, J. L., Larson, P. S., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00897-5 · Cited by 343
Valentín, A., García Navarrete, E., Chelvarajah, R., Torres, C., Navas, M., Vico, L., Torres, N., Pastor, J., Selway, R., Sola, R. G., et al. (2013) · Epilepsia · doi:10.1111/epi.12352 · Cited by 272
Adaptive deep brain stimulation in a freely moving parkinsonian patient
Rosa, M., Arlotti, M., Ardolino, G., Cogiamanian, F., Marceglia, S., Di Fonzo, A., Cortese, F., Rampini, P. M., & Priori, A. (2015) · Movement Disorders · doi:10.1002/mds.26241 · Cited by 255
Witt, K., Granert, O., Daniels, C., Volkmann, J., Falk, D., van Eimeren, T., & Deuschl, G. (2013) · Brain · doi:10.1093/brain/awt151 · Cited by 211
“The lesion caused by the insertion of the stimulating lead is held responsible for a slight and often transient improvement in motor functions (Mann et al., 2009).”
BackgroundAn update on best practice of deep brain stimulation in Parkinson’s disease
Hartmann, C. J., Fliegen, S., Groiss, S. J., Wojtecki, L., & Schnitzler, A. (2019) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756286419838096 · Cited by 173
Deep brain stimulation of the medial forebrain bundle: Distinctive responses in resistant depression
Fenoy, A. J., Schulz, P., Selvaraj, S., Burrows, C., Spiker, D., Cao, B., Zunta-Soares, G., Gajwani, P., Quevedo, J., & Soares, J. (2016) · Journal of Affective Disorders · doi:10.1016/j.jad.2016.05.064 · Cited by 125
“…not uncommonly seen after insertion of electrodes prior to turning on stimulation when treating other neurological diseases with DBS such as tremor (Mann et al., 2009) or Parkinson's disease (Morishita et al., 2010), possibly due to own relative to the actual location of implanted electrodes on…”
Background
Metadata
- Authors
- Mann, J. M., Foote, K. D., Garvan, C. W., Fernandez, H. H., Jacobson, C. E., Rodriguez, R. L., Haq, I. U., Siddiqui, M. S., Malaty, I. A., Morishita, T., Hass, C. J., & Okun, M. S.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 2009-02-22
- Volume
- 80
- Issue
- 7
- Pages
- 794-798
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W1969088624
- Cited by
- 146
- References
- 0
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.