The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Electrophysiological findings in entrapment of the median nerve at wrist and elbow
Open accessAbstract
In 117 consecutive patients with carpal tunnel syndrome and 11 patients with a compression syndrome of the median nerve at elbow, motor and sensory conduction along the median and ulnar nerves and quantitative electromyography were compared with findings in 190 normal controls of the same age. In 25% of patients with carpal tunnel syndrome in whom motor conduction and EMG were normal, the lesion was located from abnormalities in sensory conduction. The fact that conduction along the same fibres was moderately slowed from digit to palm, severely slowed across the flexor retinaculum, and normal from wrist to elbow indicates that slowing was due to demyelination at the site of compression. Fifteen per cent of the patients with carpal tunnel syndrome had clinical and electrophysiological signs of ulnar involvement. In the other patients conduction along the ulnar nerve was as in 100 normal controls. Compression at the elbow was located by electromyographical findings rather than by abnormalities in conduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experiments on the mechanism of nerve growth
Weiss, P., & Hiscoe, H. B. (1948) · Journal of Experimental Zoology · doi:10.1002/jez.1401070302 · Cited by 828
Evoked action potentials and conduction velocity in human sensory nerves
Buchthal, F., & Rosenfalck, A. (1966) · Brain Research · doi:10.1016/0006-8993(66)90056-4 · Cited by 756
Self-citationTHE INTRANEURAL TOPOGRAPHY OF THE RADIAL, MEDIAN AND ULNAR NERVES
SUNDERLAND, S. (1945) · Brain · doi:10.1093/brain/68.4.243 · Cited by 426 · cited 2×
“The cutaneous fibres from digit I and from the first, second, and third interspace lie in separate funiculi within the median nerve up to 2 cm proximal to the radial styloid line (Sunderland, 1945).”
BackgroundSENSORY NERVE ACTION POTENTIALS IN PATIENTS WITH PERIPHERAL NERVE LESIONS
Gilliatt, R. W., & Sears, T. A. (1958) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.21.2.109 · Cited by 283
ELECTRICAL SIGNS IN THE DIAGNOSIS OF CARPAL TUNNEL AND RELATED SYNDROMES
Simpson, J. A. (1956) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.19.4.275 · Cited by 265
Spontaneous electrical activity of human muscle
Buchthal, F., & Rosenfalck, P. (1966) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(66)90001-0 · Cited by 187
Self-citationNerve conduction studies in man
Mayer, R. F. (1963) · Neurology · doi:10.1212/wnl.13.12.1021 · Cited by 178
Mannerfelt, L. (1966) · Acta Orthopaedica Scandinavica · doi:10.3109/ort.1966.37.suppl-87.01 · Cited by 157
Motor Unit Potentials at Different Ages
Sacco, G., Buchthal, F., & Rosenfalck, P. (1962) · Archives of Neurology · doi:10.1001/archneur.1962.00450230028004 · Cited by 119
Self-citationA CLINICAL AND ELECTRICAL STUDY OF ULNAR NERVE LESIONS IN THE HAND
Ebeling, P. R., Gilliatt, R. W., & Thomas, P. K. (1960) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.23.1.1 · Cited by 98
Hongell, A., & Mattsson, H. S. (1971) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844317109042948 · Cited by 70
Low noise alternating current amplifier and compensator to reduce stimulus artefact
Andersen, V. O., & Buchthal, F. (1970) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477187 · Cited by 29
Self-citation
Cited by
AAEM Quality Assurance Committee, Jablecki, C. K., Andary, C. M. T., So, Y. T., Wilkins, D. E., & Williams, F. H. (1993) · Muscle & Nerve · doi:10.1002/mus.880161220 · Cited by 707
Carpal tunnel syndrome: Prevalence in the general population
De Krom, M. C. T. F. M., Knipschild, P. G., Kester, A. D. M., Thijs, C. T., Boekkooi, P. F., & Spaans, F. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90038-o · Cited by 562
AAEM minimonograph #26: The electrodiagnosis of carpal tunnel syndrome
Stevens, J. C. (1997) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199712)20:12 · Cited by 518
AAEE minimonograph #26: The electrodiagnosis of carpal tunnel syndrome
Stevens, J. C. (1987) · Muscle & Nerve · doi:10.1002/mus.880100202 · Cited by 504
Effects of age, sex, and anthropometric factors on nerve conduction measures
Stetson, D. S., Albers, J. W., Silverstein, B. A., & Wolfe, R. A. (1992) · Muscle & Nerve · doi:10.1002/mus.880151007 · Cited by 311
Metadata
- Authors
- Buchthal, F., Rosenfalck, A., & Trojaborg, W.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 1974-03-01
- Volume
- 37
- Issue
- 3
- Pages
- 340-360
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2154031239
- Cited by
- 280
- References
- 12
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.