The DOI matches its Crossref record.
Macro EMG, a new recording technique.
Open accessAbstract
A new electromyographic technique for the study of the motor unit is described. A modified single fibre EMG electrode is used. The electrical activity obtained by the electrode shaft during voluntary muscle contraction is averaged after triggering from a single muscle fibre action potential and the contribution from one motor unit is thus extracted. This "Macro EMG" signal gives information about the whole motor unit in contrast to the regional or focal electrical activity measured by conventional or single fibre EMG recordings, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Invited Review: Aging and sarcopenia
Doherty, T. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00347.2003 · Cited by 1,764
“Is there any support for such a hypothesis? Electrophysiological studies that used either macro electromyographic techniques (118) or motor unit number estimation techniques (30, 33) have demonstrated substantive losses of whole functioning motor units in proximal and distal muscles in the upper and lower extremities…”
A Guide for Use and Interpretation of Kinesiologic Electromyographic Data
Soderberg, G. L., & Knutson, L. M. (2000) · Physical Therapy · doi:10.1093/ptj/80.5.485 · Cited by 538
Effects of Ageing on the Motor Unit: A Brief Review
Doherty, T. J., Vandervoort, A. A., & Brown, W. F. (1993) · Canadian Journal of Applied Physiology · doi:10.1139/h93-029 · Cited by 358
Training adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
EMG signal decomposition: how can it be accomplished and used?
Stashuk, D. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00050-x · Cited by 268
Standards for quantification of EMG and neurography
Stålberg, E., van Dijk, H., Falck, B., Kimura, J., Neuwirth, C., Pitt, M., Podnar, S., Rubin, D. I., Rutkove, S., Sanders, D. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.05.008 · Cited by 254
Daube, J. R., & Rubin, D. I. (2009) · Muscle & Nerve · doi:10.1002/mus.21180 · Cited by 243
Sarcopenia: prevalence, mechanisms, and functional consequences
Berger, M. J., & Doherty, T. J. (2010) · Interdisciplinary topics in gerontology and geriatrics · doi:10.1159/000319997 · Cited by 175
Neurogenic Changes in the Upper Airway of Patients with Obstructive Sleep Apnea
Saboisky, J. P., Stashuk, D. W., Hamilton-Wright, A., Carusona, A. L., Campana, L. M., Trinder, J., Eckert, D. J., Jordan, A. S., McSharry, D. G., White, D. P., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201106-1058oc · Cited by 119
Metadata
- Authors
- Stalberg, E.
- Venue
- Journal of Neurology, Neurosurgery & Psychiatry
- Publisher
- BMJ
- Published
- 1980-06-01
- Volume
- 43
- Issue
- 6
- Pages
- 475-482
- ISSN
- 0022-3050 (ISSN-L)
- OpenAlex
- W2134349396
- Cited by
- 237
- References
- 0
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.