Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record.

Carpal tunnel syndrome (CTS) and exposure to vibration, repetitive wrist movements, and heavy manual work: a case-referent study.

Open access
Wieslander, G, Norback, D, Gothe, C J, Juhlin, L·1989·Occupational and Environmental Medicine

Abstract

1732 Objectives Gastrin-releasing peptide receptor (GRPR) is an established target for imaging GRPR positive prostate and breast cancers. The aim of this work was to evaluate Al18F-NOTA labeled bombesin congener in vitro and in vivo and compare to previously synthesized 18F and 68Ga analogues. Methods 4-amino-1-carboxymethyl-piperidine-D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2 was conjugated to NOTA chelating agent giving precursor 1. Radiolabeling was performed using Al18F method. The reagents were heated in ethanol/0.1 M sodium acetate buffer pH 4.1 (1:2) at 105°C for 10 min. Separation of unreacted 18F-fluoride and inorganic salts was achieved by solid phase extraction using HLB Plus cartridge. Specific activity was calculated based on the initial quantity of the precursor used for the radiolabeling. PET imaging of PC-3 tumor xenografted mice was performed using a GE eXplore Vista PET/CT. Blocking studies were conducted in the presence of 50 µg bombesin. Biodistribution was done at 135 min post-injection. Results The radiolabeling with Al18F was quick (under 30 min, including formulation) and robust, giving Al18F-1 (Ki = 0.68 ± 0.06 nM, logD7.4 = -3.3) in 34 ± 8 % radiochemical yield (d.c.) with specific activities 25-50 GBq/μmol (0.7-1.6 Ci/μmol) (EOS). Ethanol as co-solvent decreased radiolysis during synthesis. In vivo PET studies using Al18F-1 showed high accumulation in tumor with excellent contrast. The biodistribution results indicated high radioactivity in the pancreas (5-20 %ID/g). Intestine, gallbladder and kidneys accumulated below 2 %ID/g each. Tumor uptake was 4.5 ± 0.8 %ID/g. Tumor to blood and tumor to muscle ratios were 58 and 57, respectively. The binding decreased at blocking conditions to 1.6 ± 0.4 %ID/g, confirming specificity. Conclusions Al18F-1 is a promising tracer to image GRPR positive tumors. It was superior to the in-house clinical PoM bombesin analogue in delineating PC-3 tumor in mice

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/oem.46.1.43

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 207

Metadata

Authors
Wieslander, G., Norback, D., Gothe, C. J., & Juhlin, L.
Venue
Occupational and Environmental Medicine
Publisher
BMJ
Published
1989-01-01
Volume
46
Issue
1
Pages
43-47
ISSN
  • 0007-1072 (ISSN-L)
  • 1351-0711
OpenAlex
W2010784890
Cited by
207
References
0
FWCI
6.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Carpal tunnel syndrome (CTS) and exposure to vibration, repetitive wrist movements, and heavy manual work: a case-referent study. https://app.cochat.ai/papers/10.1136/oem.46.1.43
The paper
Wieslander, G., Norback, D., Gothe, C. J., & Juhlin, L. (1989). Carpal tunnel syndrome (CTS) and exposure to vibration, repetitive wrist movements, and heavy manual work: a case-referent study. Occupational and Environmental Medicine. https://doi.org/10.1136/oem.46.1.43

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.