The DOI matches its Crossref record.
Experimental exposure to propylene glycol mist in aviation emergency training: acute ocular and respiratory effects
Open accessAbstract
OBJECTIVES: Propylene glycol (PG) (1–2 propanediol; CAS No 57–55–6) is a low toxicity compound widely used as a food additive, in pharmaceutical preparations, in cosmetics, and in the workplace—for example, water based paints, de-icing fluids, and cooling liquids. Exposure to PG mist may occur from smoke generators in discotheques, theatres, and aviation emergency training. Propylene glycol may cause contact allergy, but there is sparse information on health effects from occupational exposure to PG. METHODS: Non-asthmatic volunteers (n=27) were exposed in an aircraft simulator to PG mist over 1 minute, during realistic training conditions. Geometric mean concentration of PG was 309 mg/m 3(range 176–851 mg/m 3), with the highest concentrations in the afternoon. The medical investigation was performed both before and after the exposure (within 15 minutes). It included an estimate of tear film stability break up time, nasal patency by acoustic rhinometry, dynamic spirometry, and a doctor's administered questionnaire on symptoms. RESULTS: After exposure to PG mist for 1 minute tear film stability decreased, ocular and throat symptoms increased, forced expiratory volume in 1 second/forced vital capacity (FEV 1/FVC) was slightly reduced, and self rated severity of dyspnoea was slightly increased. No effect was found for nasal patency, vital capacity (VC), FVC, nasal symptoms, dermal symptoms, smell of solvent, or any systemic symptoms. Those exposed to the higher concentrations in the afternoon had a more pronounced increase of throat symptoms, and a more pronounced decrease of tear film stability. In four subjects who reported development of irritative cough during exposure to PG, FEV 1 was decreased by 5%, but FEV 1 was unchanged among those who did not develop a cough. Those who developed a cough also had an increased perception of mild dyspnoea. CONCLUSION: Short exposure to PG mist from artificial smoke generators may cause acute ocular and upper airway irritation in non-asthmatic subjects. A few may also react with cough and slight airway obstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Highly Stretchable and Tough Hydrogels below Water Freezing Temperature
Morelle, X. P., Illeperuma, W. R., Tian, K., Bai, R., Suo, Z., & Vlassak, J. J. (2018) · Advanced Materials · doi:10.1002/adma.201801541 · Cited by 647
Farsalinos, K. E., & Polosa, R. (2014) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098614524430 · Cited by 594
Short-term Pulmonary Effects of Using an Electronic Cigarette
Vardavas, C. I., Anagnostopoulos, N., Kougias, M., Evangelopoulou, V., Connolly, G. N., & Behrakis, P. K. (2012) · Chest · doi:10.1378/chest.11-2443 · Cited by 532
What are the respiratory effects of e-cigarettes?
Gotts, J. E., Jordt, S.-E., McConnell, R., & Tarran, R. (2019) · BMJ · doi:10.1136/bmj.l5275 · Cited by 516
A systematic review of health effects of electronic cigarettes
Pisinger, C., & Døssing, M. (2014) · Preventive Medicine · doi:10.1016/j.ypmed.2014.10.009 · Cited by 484
An updated overview of e-cigarette impact on human health
Marques, P., Piqueras, L., & Sanz, M.-J. (2021) · Respiratory Research · doi:10.1186/s12931-021-01737-5 · Cited by 470
Schober, W., Szendrei, K., Matzen, W., Osiander-Fuchs, H., Heitmann, D., Schettgen, T., Jörres, R. A., & Fromme, H. (2014) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2013.11.003 · Cited by 458
Emissions from Electronic Cigarettes: Key Parameters Affecting the Release of Harmful Chemicals
Sleiman, M., Logue, J. M., Montesinos, V. N., Russell, M. L., Litter, M. I., Gundel, L. A., & Destaillats, H. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b01741 · Cited by 446
Polosa, R., Caponnetto, P., Morjaria, J. B., Papale, G., Campagna, D., & Russo, C. (2011) · BMC Public Health · doi:10.1186/1471-2458-11-786 · Cited by 432
Sussan, T. E., Gajghate, S., Thimmulappa, R. K., Ma, J., Kim, J.-H., Sudini, K., Consolini, N., Cormier, S. A., Lomnicki, S., Hasan, F., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0116861 · Cited by 429
Schripp, T., Markewitz, D., Uhde, E., & Salthammer, T. (2013) · Indoor Air · doi:10.1111/j.1600-0668.2012.00792.x · Cited by 420
Electronic Cigarettes: A Policy Statement From the American Heart Association
Bhatnagar, A., Whitsel, L. P., Ribisl, K. M., Bullen, C., Chaloupka, F., Piano, M. R., Robertson, R. M., McAuley, T., Goff, D., & Benowitz, N. (2014) · Circulation · doi:10.1161/cir.0000000000000107 · Cited by 392
Chemical hazards present in liquids and vapors of electronic cigarettes
Hutzler, C., Paschke, M., Kruschinski, S., Henkler, F., Hahn, J., & Luch, A. (2014) · Archives of Toxicology · doi:10.1007/s00204-014-1294-7 · Cited by 348
Han, Z., Wang, P., Lu, Y., Jia, Z., Qu, S., & Yang, W. (2022) · Science Advances · doi:10.1126/sciadv.abl5066 · Cited by 322
Pulmonary toxicity of e-cigarettes
Chun, L. F., Moazed, F., Calfee, C. S., Matthay, M. A., & Gotts, J. E. (2017) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00071.2017 · Cited by 311
Association of E-Cigarette Use With Respiratory Disease Among Adults: A Longitudinal Analysis
Bhatta, D. N., & Glantz, S. A. (2020) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2019.07.028 · Cited by 292
Wolkoff, P., Nøjgaard, J. K., Troiano, P., & Piccoli, B. (2005) · Occupational and Environmental Medicine · doi:10.1136/oem.2004.016030 · Cited by 259
Nguyen, T., Li, G. E., Chen, H., Cranfield, C. G., McGrath, K. C., & Gorrie, C. A. (2018) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.8b00084 · Cited by 135
Metadata
- Authors
- Wieslander, G., Norbäck, D., & Lindgren, T.
- Venue
- Occupational and Environmental Medicine
- Publisher
- BMJ
- Published
- 2001-10-01
- Volume
- 58
- Issue
- 10
- Pages
- 649-655
- ISSN
- 0007-1072 (ISSN-L)
- 1351-0711
- 1470-7926
- OpenAlex
- W2092908361
- Cited by
- 224
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.