CoChat

The DOI matches its Crossref record, with a small difference in title or year; 22 of the 22 references it cites were found in a registry or an index.

Diagnostic performance of morning serum cortisol as an alternative to short synacthen test for the assessment of adrenal reserve; a retrospective study

Kumar, Rajeev, Carr, Peter, Wassif, Ws · 2022 · Postgraduate Medical Journal

Abstract

OBJECTIVE: The short synacthen test (SST) is widely used across the UK to assess adrenal reserve. The main objective of our study was to determine the morning serum cortisol level that will predict adrenal insufficiency (AI) thus reducing our reliance on SST. DESIGN: This was a single centre retrospective study of 393 SST tests measuring 0 and 60 min cortisol levels after administration of 250 μg of synacthen (synthetic ACTH). PATIENTS AND METHODS: All the SST tests for patients suspected of primary or secondary AI between April 2016 and October 2018 were included in this study. We used serum to determine circulating cortisol by a newer generation competitive electrochemiluminescence immunoassay (ECLIA) (Roche Diagnostics). A post-ACTH cortisol response of ≥420 nmol/L at 60 min was considered adequate to rule out AI. The data were analysed to ascertain the relationship between 0 min and 60 min serum cortisol. RESULTS: A total of 393 SST results were included in this study. Overall, a total of 332 (84.5%) subjects achieved sufficient serum cortisol level at 60 min, while 61 subjects (15.5%) showed insufficient response. Using the logistic regression, we determined that a morning basal serum cortisol level of ≥354 nmol/L was able to predict normal adrenal function with 100% sensitivity. We were unable to find a lower cut-off value below which SST will not be required. By using this proposed cut-off point, approximately 37% of the SSTs tests could be avoided. CONCLUSIONS: Basal morning serum cortisol can be safely used as a first step in the evaluation of patients with suspected AI. This will enhance the number of patients being screened for this condition.

Overview

Integrity signals

Registry

Crossref · 10.1136/postgradmedj-2020-138514

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Research works printed but not linked: 2

  1. Society for Endocrinology, Department of health advice on synacthen shortage
  2. Cortisol, 2017, User manual, COBAS, Roche diagnostics

Cited by

See all 23

Metadata

Authors
Kumar, R., Carr, P., & Wassif, W.
Affiliations
  • Bedford Hospital NHS Trust (GB)
  • The Alan Turing Institute (GB)
Corresponding author
Kumar, Rajeev
Venue
Postgraduate Medical Journal
Published
2020-10-29
Volume
98
Issue
1156
Pages
113-118
ISSN
  • 0032-5473 (ISSN-L)
  • 1469-0756
OpenAlex
W3096788302
Cited by
23
References
22
Citations by year
2026: 2 · 2025: 7 · 2024: 7 · 2023: 3 · 2022: 4
FWCI
1.32
Type
journal article
Language
en
Open access
closed
Locations
  • Postgraduate Medical Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
adrenal insufficiency, ACTH stimulation test, basal cortisol, adrenal reserve, diagnostic accuracy, screening, electrochemiluminescence immunoassay
MeSH terms
Adrenal Insufficiency, Adult, Aged, Cosyntropin, Diagnostic Tests, Routine, Female, Humans, Hydrocortisone, Male, Middle Aged, Retrospective Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic performance of morning serum cortisol as an alternative to short synacthen test for the assessment of adrenal reserve; a retrospective study. https://app.cochat.ai/papers/10.1136/postgradmedj-2020-138514
The paper
Kumar, R., Carr, P., & Wassif, W. (2022). Diagnostic performance of morning serum cortisol as an alternative to short synacthen test for the assessment of adrenal reserve; a retrospective study. Postgraduate Medical Journal. https://doi.org/10.1136/postgradmedj-2020-138514

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.