The DOI matches its Crossref record.
Human factors engineering and patient safety
Open accessAbstract
Objective: To determine the diagnostic value of high-resolution ultrasound (HRUS) for detection of chronic inflammatory demyelinating polyneuropathy (CIDP), Lewis-Sumner syndrome (LSS), and multifocal motor neuropathy (MMN). Methods: Between January 2013 and January 2015, we enrolled 75 consecutive treatment-naive patients with chronic inflammatory neuropathies and 70 disease controls. We performed extensive nerve conduction and standardized HRUS studies bilaterally of large arm and leg nerves and brachial plexus. We determined optimal sonographic cutoff values of nerve size and used receiver operating characteristic analysis and logistic regression models to identify nerve combinations with optimal diagnostic performance. Results: Enlargement of median nerve at forearm >10 mm2, upper arm >13 mm2, and any trunk of brachial plexus >8 mm2 was 99% specific for chronic inflammatory neuropathies. A shortened HRUS protocol for detecting this abnormal nerve enlargement showed high sensitivity (83%–95%), positive predictive value (100%), and negative predictive value (98%) in discriminating CIDP, LSS, and MMN from clinical mimics. Conclusions: Sonographic enlargement of proximal median nerve segments in the arms and brachial plexus is a key feature of chronic inflammatory neuropathies, which helps to reliably distinguish them from axonal neuropathies and amyotrophic lateral sclerosis. Classification of evidence: This study provides Class II evidence that, in absence of clinical features that suggest a hereditary demyelinating neuropathy, sonographic enlargement of proximal median nerve segments and brachial plexus accurately identifies patients with chronic inflammatory neuropathies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coté, C. J., Wilson, S., AMERICAN ACADEMY OF PEDIATRICS, & AMERICAN ACADEMY OF PEDIATRIC DENTISTRY (2019) · Pediatrics · doi:10.1542/peds.2019-1000 · Cited by 1,406
Sax, H., Allegranzi, B., Uçkay, I., Larson, E., Boyce, J., & Pittet, D. (2007) · Journal of Hospital Infection · doi:10.1016/j.jhin.2007.06.004 · Cited by 808
American Academy of Pediatrics, American Academy of Pediatric Dentistry, Coté, C. J., Wilson, S., & the Work Group on Sedation (2006) · Pediatrics · doi:10.1542/peds.2006-2780 · Cited by 555
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Beyond usability: Designing effective technology implementation systems to promote patient safety
Karsh, B.-T. (2004) · Quality and Safety in Health Care · doi:10.1136/qshc.2004.010322 · Cited by 414
Metadata
- Authors
- Gosbee, J.
- Venue
- Quality and Safety in Health Care
- Publisher
- BMJ
- Published
- 2002-12-01
- Volume
- 11
- Issue
- 4
- Pages
- 352-354
- ISSN
- 1475-3898 (ISSN-L)
- 1475-3901
- OpenAlex
- W2142463759
- Cited by
- 195
- References
- 0
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human factors engineering and patient safety. https://app.cochat.ai/papers/10.1136/qhc.11.4.352
- The paper
- Gosbee, J. (2002). Human factors engineering and patient safety. Quality and Safety in Health Care. https://doi.org/10.1136/qhc.11.4.352
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.