CoChat

Continuous positive airway pressure for sleep apnoea/hypopnoea syndrome: usefulness of a 2 week trial to identify factors associated with long term use

Open access
Popescu, G · 2001 · Thorax
Cited by 145

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The sleep apnoea/hypopnoea syndrome (SAHS) is common and treatment with continuous positive airway pressure (CPAP) is effective. However, not all patients can cope with the demands of using mask positive pressure. Compliance can be improved with an intensive educational programme and patient support, but this is not practical in most centres given the large numbers of patients coming forward for treatment. Several studies have evaluated correlations between various parameters at diagnosis in order to anticipate patients' behaviour and to avoid the social and health implications of undertreated SAHS. We have evaluated the use of additional data derived during a 2 week home CPAP trial to identify factors associated with longer term use of CPAP and compliance. METHODS: Following a diagnostic study, 209 patients were offered a CPAP machine for a 2 week home trial. After completing the trial, patients were reassessed and scored their overall satisfaction with CPAP treatment on a five point scale ranging from "much worse" to "much better" and an Epworth score relating to the loan period. Machine run time was recorded from the integral clock. These data were added to those available at diagnosis to construct models indicative of continuing CPAP and average nightly use at 1 year. RESULTS: 209 patients were offered the 2 week loan at least a year before June 1999 (90.9% men, mean (SD) age 51.0 (10.6) years, body mass index (BMI) 34.6 (7.7) kg/m(2), Epworth score 15 (IQR 11-18), apnoea/hypopnoea index (AHI) 38.1 (22.9) events/h). 153 patients (73.2%) opted to continue CPAP and 56 declined. One year later data were available for 187 patients; 128 (68.5% on an intention to treat analysis) continued to use the machine with a mean use of 5.0 (2.4) hours/night. A logistic regression model indicated that mean CPAP use during the loan period and the overall satisfaction score accurately defined continuing CPAP and "satisfactory" CPAP use at 1 year. For patients with low machine use and no symptomatic improvement during the loan period, the addition of baseline AHI, baseline Epworth score, and the Epworth score at the end of the loan to the equation identifying factors associated with "satisfactory" CPAP use (mean >2 hours/night) improved the value of the model. CONCLUSION: Data derived from a 2 week CPAP trial are useful in identifying patients who will comply with CPAP treatment to 1 year. It can be used to identify patients with significant symptomatic disease who will struggle with CPAP and may benefit from additional education and support. High mean hourly use and a high degree of overall satisfaction during the loan period identified patients likely to use CPAP and be compliant with it at 1 year.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thorax.56.9.727

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 145

Metadata

Authors
Popescu, G.
Venue
Thorax
Publisher
BMJ
Published
2001-09-01
Volume
56
Issue
9
Pages
727-733
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2118297767
Cited by
145
References
8
FWCI
2.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous positive airway pressure for sleep apnoea/hypopnoea syndrome: usefulness of a 2 week trial to identify factors associated with long term use. https://app.cochat.ai/papers/10.1136/thorax.56.9.727
The paper
Popescu, G. (2001). Continuous positive airway pressure for sleep apnoea/hypopnoea syndrome: usefulness of a 2 week trial to identify factors associated with long term use. Thorax. https://doi.org/10.1136/thorax.56.9.727

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.