OBJECTIVES: The aim of this study was to test the effectiveness of Provent, an expiratory nasal resistance valve, to prevent the recurrence of OSA following CPAP withdrawal. DESIGN: Randomised, partially blinded, parallel, placebo-controlled trial. SETTING: Outpatient sleep clinics in the UK (Oxford) and Switzerland (Zurich). PARTICIPANTS: 67 patients with OSA receiving CPAP were randomised to one of three groups for 2 weeks: continuing CPAP, Provent or placebo Provent. MAIN OUTCOME MEASURES: Primary outcomes included for Provent versus placebo Provent, OSA severity (oxygen desaturation index (ODI), apnoea-hypopnoea index (AHI)) and Epworth Sleepiness Scale (ESS) score. Secondary outcomes for Provent versus placebo Provent included ODI from ambulatory pulse oximetry and blood pressure (BP). For CPAP versus Provent, or CPAP versus placebo Provent, secondary outcomes included ODI/AHI, ESS and BP. RESULTS: 63 patients were included in the per protocol analysis. OSA recurred in the Provent (ODI 35.8, SD 17.4) and placebo Provent (ODI 28.2, SD 18.3) groups, and there was no significant difference in ODI, AHI and ESS between Provent and placebo Provent at 2 weeks (mean difference ODI -1.0, 95% CI -10.0 to +12.0, p=0.85; AHI +3.2, 95% CI -7.7 to +14.1, p=0.52; and ESS -1.4, 95% CI -4.1 to +1.4, p=0.33). ODI from ambulatory pulse-oximetry and BP at 2 weeks were not different in the Provent versus placebo Provent groups. ODI, AHI and BP, but not ESS, were significantly higher in the Provent and placebo Provent groups compared with CPAP. CONCLUSIONS: Provent cannot be recommended as an alternative short-term therapy for patients with moderate to severe OSA already on CPAP. TRIALREGNO: NCT01332175.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thoraxjnl-2013-203508

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 42

Metadata

Authors
Rossi, V. A., Winter, B., Rahman, N. M., Yu, L.-M., Fallon, J., Clarenbach, C. F., Bloch, K. E., Stradling, J. R., & Kohler, M.
Venue
Thorax
Publisher
BMJ
Published
2013-05-30
Volume
68
Issue
9
Pages
854-859
ISSN
  • 0040-6376 (ISSN-L)
  • 1468-3296
OpenAlex
W2171484416
Cited by
42
References
4
FWCI
5.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of Provent on moderate to severe obstructive sleep apnoea during continuous positive airway pressure therapy withdrawal: a randomised controlled trial. https://app.cochat.ai/papers/10.1136/thoraxjnl-2013-203508
The paper
Rossi, V. A., Winter, B., Rahman, N. M., Yu, L.-M., Fallon, J., Clarenbach, C. F., Bloch, K. E., Stradling, J. R., & Kohler, M. (2013). The effects of Provent on moderate to severe obstructive sleep apnoea during continuous positive airway pressure therapy withdrawal: a randomised controlled trial. Thorax. https://doi.org/10.1136/thoraxjnl-2013-203508

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.