Patterns of dynamic hyperinflation during exercise and recovery in patients with severe chronic obstructive pulmonary disease
Open accessAbstract
BACKGROUND: Not all patients with severe chronic obstructive pulmonary disease (COPD) progressively hyperinflate during symptom limited exercise. The pattern of change in chest wall volumes (Vcw) was investigated in patients with severe COPD who progressively hyperinflate during exercise and those who do not. METHODS: Twenty patients with forced expiratory volume in 1 second (FEV(1)) 35 (2)% predicted were studied during a ramp incremental cycling test to the limit of tolerance (Wpeak). Changes in Vcw at the end of expiration (EEVcw), end of inspiration (EIVcw), and at total lung capacity (TLCVcw) were computed by optoelectronic plethysmography (OEP) during exercise and recovery. RESULTS: Two significantly different patterns of change in EEVcw were observed during exercise. Twelve patients had a progressive significant increase in EEVcw during exercise (early hyperinflators, EH) amounting to 750 (90) ml at Wpeak. In contrast, in all eight remaining patients EEVcw remained unchanged up to 66% Wpeak but increased significantly by 210 (80) ml at Wpeak (late hyperinflators, LH). Although at the limit of tolerance the increase in EEVcw was significantly greater in EH, both groups reached similar Wpeak and breathed with a tidal EIVcw that closely approached TLCVcw (EIVcw/TLCVcw 93 (1)% and 93 (3)%, respectively). EEVcw was increased by 254 (130) ml above baseline 3 minutes after exercise only in EH. CONCLUSIONS: Patients with severe COPD exhibit two patterns during exercise: early and late hyperinflation. In those who hyperinflate early, it may take several minutes before the hyperinflation is fully reversed after termination of exercise.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Because TLC remains stable during exercise, a temporary decrease in IC reflects a temporary increase in EELV.
“Because TLC remains stable during exercise,148,149 a temporary decrease in IC reflects a temporary increase in EELV”
From Pathogenesis of hyperinflation in chronic obstructive pulmonary disease (2014) · cites this paper as [149]
Cites
Belman, M. J., Botnick, W. C., & Shin, J. W. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.153.3.8630581 · Cited by 402 · see citing works
Regional chest wall volumes during exercise in chronic obstructive pulmonary disease
Aliverti, A. (2004) · Thorax · doi:10.1136/thorax.2003.011494 · Cited by 226 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Physiology and consequences of lung hyperinflation in COPD
O'Donnell, D. E., & Laveneziana, P. (2006) · European Respiratory Review · doi:10.1183/09059180.00010002 · Cited by 223 · see citing works
Dyspnea and Activity Limitation in COPD: Mechanical Factors
O'Donnell, D. E., & Laveneziana, P. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701480455 · Cited by 220 · see citing works
Pathogenesis of hyperinflation in chronic obstructive pulmonary disease
Saey, Gagnon, P., Guenette, J., Langer, D., Laviolette, L., Mainguy, V., Maltais, F., & Ribeiro, F. (2014) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s38934 · Cited by 180 · see citing works
Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation
Massaroni, C., Venanzi, C., Silvatti, A. P., Lo Presti, D., Saccomandi, P., Formica, D., Giurazza, F., Caponero, M. A., & Schena, E. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700263 · Cited by 139 · see citing works
- Authors
- Vogiatzis, I.
- Affiliations
- National and Kapodistrian University of Athens (GR)
- Corresponding author
- Vogiatzis, I
- ORCID
- Vogiatzis, I
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2005-09-01
- Volume
- 60
- Issue
- 9
- Pages
- 723-729
- ISSN
- 0040-6376 (ISSN-L)
- PMC
- PMC1747529
- OpenAlex
- W2172190292
- Cited by
- 121
- References
- 2
- Citations by year
- 2026: 2 · 2024: 1 · 2023: 1 · 2021: 6 · 2020: 4 · 2019: 4 · 2018: 7 · 2017: 2 · 2016: 4 · 2015: 8 · 2014: 9 · 2013: 11 · 2012: 16
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Thorax (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Keywords
- chronic obstructive pulmonary disease, dynamic hyperinflation, chest wall volume, post-exercise recovery, optoelectronic plethysmography, incremental cycling test, tidal volume, total lung capacity
- MeSH terms
- Inhalation, Female, Forced Expiratory Volume, Humans, Lung Volume Measurements, Male, Middle Aged, Tidal Volume, Vital Capacity, Exercise, Pulmonary Disease, Chronic Obstructive, Thoracic Wall
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review