Cited by 139Non-Invasive Vital Sign MonitoringAdvanced Fiber Optic SensorsAdvanced Sensor and Energy Harvesting Materials

Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation

Open access
Massaroni, Carlo, Venanzi, Cecilia, Silvatti, Amanda P., Lo Presti, Daniela, Saccomandi, Paola, Formica, Domenico, Giurazza, Francesco, Caponero, Michele A. +1 more·2018·Journal of Biophotonics

Abstract

The use of wearable systems for monitoring vital parameters has gained wide popularity in several medical fields. The focus of the present study is the experimental assessment of a smart textile based on 12 fiber Bragg grating sensors for breathing monitoring and thoraco-abdominal motion pattern analysis. The feasibility of the smart textile for monitoring several temporal respiratory parameters (ie, breath-by-breath respiratory period, breathing frequency, duration of inspiratory and expiratory phases), volume variations of the whole chest wall and of its compartments is performed on 8 healthy male volunteers. Values gathered by the textile are compared to the data obtained by a motion analysis system, used as the reference instrument. Good agreement between the 2 systems on both respiratory period (bias of 0.01 seconds), breathing frequency (bias of -0.02 breaths/min) and tidal volume (bias of 0.09 L) values is demonstrated. Smart textile shows good performance in the monitoring of thoraco-abdominal pattern and its variation, as well.

Integrity signals

Registry

Crossref · 10.1002/jbio.201700263

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Combining 12 fiber Bragg grating sensors into one smart textile performed detailed thoracic-abdominal motion pattern analysis with respiratory period error of 0.2 rpm and tidal volume error of 0.09 L.

    “Sometimes researchers combined even 12 fiber Bragg grating sensors into one smart textile [257] to perform a detailed thoracic-abdominal motion pattern analysis and achieved good accuracy of the respiratory period (error 0.2 rpm) and tidal volume (error 0.09 L).”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [257]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Massaroni, C., Venanzi, C., Silvatti, A. P., Lo Presti, D., Saccomandi, P., Formica, D., Giurazza, F., Caponero, M. A., & Schena, E.
Affiliations
  • Università Campus Bio-Medico (IT)
  • Universidade Federal de Viçosa (BR)
  • Unit of Measurements and Biomedical Instrumentation, Department of Engineering Università Campus Bio‐Medico di Roma Rome Italy
  • Institut de Chirurgie Guidée par l'Image (FR)
  • Photonics Micro‐ and Nanostructures Laboratory Research Centre of Frascati Rome Italy
Corresponding author
Massaroni, Carlo
Venue
Journal of Biophotonics
Publisher
Wiley
Published
2018-02-26
Volume
11
Issue
5
Pages
e201700263-e201700263
ISSN
  • 1864-063X (ISSN-L)
  • 1864-0648
OpenAlex
W2781507917
Cited by
139
References
24
Citations by year
2026: 7 · 2025: 10 · 2024: 15 · 2023: 13 · 2022: 14 · 2021: 15 · 2020: 28 · 2019: 25 · 2018: 12
FWCI
8.00
Type
journal article
Language
en
Open access
Locations
  • Journal of Biophotonics (publishedVersion)
  • PubMed (publishedVersion)
  • Americanae (AECID Library) (publishedVersion, other-oa)
  • Americanae (AECID Library) (submittedVersion, other-oa)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, other-oa)
  • Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
Funders
Università Campus Bio-Medico di Roma
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
fiber Bragg grating sensors, respiratory monitoring, chest wall volume, respiratory rate, tidal volume, wearable sensors, vital signs monitoring
MeSH terms
Abdomen, Adult, Humans, Monitoring, Physiologic, Movement, Respiration, Textiles, Thorax, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review