CoChat

Nasal CPAP reduces systemic blood pressure in patients with obstructive sleep apnoea and mild sleepiness

Open access
Hui, D S, To, K W, Ko, F W, Fok, J P, Chan, M C, Ngai, J C, Tung, A H, Ho, C W, Tong, M W, Szeto, C-C, Yu, C-M · 2006 · Thorax
Cited by 108

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

BACKGROUND: A randomised controlled study was undertaken to examine the effect of nasal continuous positive airway pressure (CPAP) on 24 hour systemic blood pressure (BP) in patients with obstructive sleep apnoea (OSA). METHODS: Patients were fitted with an ambulatory BP measuring device as outpatients during normal activities and recorded for 24 hours before starting therapeutic or subtherapeutic (4 cm H(2)O) CPAP treatment. BP monitoring was repeated before completion of 12 weeks of treatment. The primary end point was the change in 24 hour mean BP. RESULTS: Twenty three of 28 participants in each treatment arm completed the study. There was no significant difference between the two groups in age, body mass index, Epworth Sleepiness Score, apnoea-hypopnoea index, arousal index, and minimum Sao(2). Twenty four patients were hypertensive. The pressure in the therapeutic CPAP group was 10.7 (0.4) cm H(2)O. CPAP usage was 5.1 (0.4) and 2.6 (0.4) hours/night for the therapeutic and subtherapeutic CPAP groups, respectively (p<0.001). After 12 weeks of treatment there were significant differences between the two CPAP groups in mean (SE) changes in 24 hour diastolic BP (-2.4 (1.2) v 1.1 (1.0) mm Hg (95% CI -6.6 to -0.5), p = 0.025); 24 hour mean BP (-2.5 (1.3) v 1.3 (1.1) mm Hg (95% CI -7.2 to -0.2), p = 0.037); sleep time systolic BP (-4.1 (2.1) v 2.2 (1.8) mm Hg (95% CI -11.8 to -0.7), p = 0.028); and sleep time mean BP (-3.6 (1.7) v 1.3 (1.4) mm Hg (95% CI -9.2 to -0.4), p = 0.033). CONCLUSIONS: Compared with subtherapeutic CPAP, 12 weeks of treatment with therapeutic CPAP leads to reductions in 24 hour mean and diastolic BP by 3.8 mm Hg and 3.5 mm Hg, respectively, in mildly sleepy patients with OSA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2006.064063

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 108

Metadata

Authors
Hui, D. S., To, K. W., Ko, F. W., Fok, J. P., Chan, M. C., Ngai, J. C., Tung, A. H., Ho, C. W., Tong, M. W., Szeto, C.-C., & Yu, C.-M.
Venue
Thorax
Publisher
BMJ
Published
2006-12-01
Volume
61
Issue
12
Pages
1083-1090
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2112918750
Cited by
108
References
20
FWCI
4.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.